Installation
e. Remove the four bolts from each tank located
behind cap plug at each corner. Refer to
Figure 9.
f. Lift tanks off the washer-extractor.
CAUTION
Be extremely careful when removing tanks.
To prevent damage, always place tanks on a
level surface with clean-out access facing
up.
2. Removing the pump assembly:
a. Remove manifold hose clamps connecting the
pump manifold to the drain valve found at the
5
1
Corner Tank Bolts (4 per Tank)
2
Hose Clamps on Elbows
3
Manifold Hose Clamps
20
1
4
Figure 9
rear of the washer-extractor to the right of the
pump assembly. Refer to Figure 9.
b. Unscrew the two pump motor electrical quick
disconnects from the water saving control
housing located at the rear of the washer-
extractor.
c. Slide off the long black hoses that run from
the water tanks. Refer to Figure 9.
d. Remove pump assembly and place to the side.
3. Positioning and bolting down the washer-
extractor:
Refer to Mechanical Installation Section for
boltdown instructions.
2
3
4
Pump Assembly
5
Cap Plug