FIGURE 6
There are two buttons on the front of the controller.
- Silence/Reset
• Can be pressed to silence current alarms for 24 hours.
• Can be held for longer than 3 seconds to reset high water alarm. Reset will clear flashing light on unit.
• Other alarms must be cleared by a proper function of alarm component.
- Self Test
• Will run the pump when the low water light is green (float up or jumper installed) to determine if amp draw of pump is in range. If low water float is
used, unit will pump water to determine proper pump operation of check valve and discharge piping.
• If low water float is down due to lack of water, controller will determine if pump is connected during self test, but will not run the pump due to lack
of water.
• Battery testing:
° Unit constantly monitors battery to determine if battery is connected and at proper voltage.
° The battery is load-tested after every use of the pump.
• Controller is factory programmed to self-test the pump every 24 hours for 10 seconds.
• Holding the self-test button for 10 seconds will start the 24-hour timer for self-testing.
The LED light will display information about the controller.
System Ready
AC power
Battery
DC pump
Low water
Operational switch
High water switch
Once your Aquanot
Active 508 battery backup sump pump system is fully operational, the Z Control
®
Active Controller to communicate with the Z Control
of Z Control
Enabled devices can log into their Cloud account to silence alarms and test the equipment. A constant internet connection is required. The Gateway
®
may be connected to the home's router with either an Ethernet cable or WiFi. The Gateway's connection to the Active Controller is by wire only.
For details please refer to FM2901, the Z Control
AQUANOT
ACTIVE FLOAT SWITCH
®
LOW WATER
(OPTIONAL)
OPERATIONAL
ACTIVE CONTROLLER FUNCTIONS
Solid Green
Flashing Yellow
Ready
--
--
--
Pump running
--
Pit low on water
--
System cycling/cycled
Z CONTROL
Cloud. Once properly configured, alarms can be sent to users' computers or mobile devices. Authorized users
®
Gateway Installation Instructions.
®
© Copyright 2016 Zoeller
HIGH WATER
LOCKING PIN MUST BE
INSTALLED UNDER FLOAT
ROD IN THIS LOCATION.
Flashing Red
--
--
--
No AC power
Charging
Disconnected or fault
Pump fault
Float fault
Float fault
--
Float fault
GATEWAY
®
Gateway device can be installed. The Gateway will allow your
®
Co. All rights reserved.
®
7
SK3046
Fast-flashing Red
--
--
--
--
Pump running continuously
--
High water condition