//INSTALLATION
3 – Connect the electronic unit connector that leads to the solenoid
valve to the solenoid connector.
4 – Connect the other electronic unit connector to the transformer
cable connector.
5 – Before assembling the panel, consider using the provided adjusting
screw in order to optimize the operation of the mechanical button. If
6
needed, assemble the adjusting screw to the mechanical button at the
internal side of the panel and adjust it to the desired distance.
6 – seat and Assemble the panel to the cover tighten it with the
bottom screw.
7 – This product includes a self adjusting sensor. The ideal sensor
range for the specific location will be set automatically. Right now,
check that no objects are in front of the sensor.
8 – Remove the protective sticker covering the sensor.
9 – Plug in the transformer.
10 – Wait about 30 seconds before you step or put your hand within
7
the sensor range. As an indication that the self adjusting is taking
place, a red light in the sensor eye will flash continuously. The solenoid
valve will be opened and closed for 1 second as an indication that the
ideal sensor range was set and the product is ready for use.
11 – To operate, step within the sensor range for a minimum of 8
seconds. Move away and the flush valve will flush a few seconds after
your departure.
12 – If needed adjust the flow rate by turning the regulating valve. In
order to avoid entering into the self adjusting mode, do not disconnect
8
the cables between the electronic unit and the transformer.
13 – If the range is unsatisfactory, refer to the section entitled
"Settings Adjustment".
58//59