Safety Precautions; System Operation - golmar T562 GB2 Guía Rápida

Ocultar thumbs Ver también para T562 GB2:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

T562 G 2
B
TELEPHONE

SAFETY PRECAUTIONS

- Install or modify the equipment without the power connected.
- The installation and handling of these equipments must be performed by authorised personnel.
40 cm
-
The
entire installation must be
at least
- Do not overtighten the screws on the terminal block.
-
Install the telephone in a dry
and
protected
- Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
- Before connecting the system to the mains, check the connections between the door panel,
power supply and telephones.
- Do a
lways follow
the enclosed information
CHARACTERISTICS
( )
*
- Telephone with simple installation (2 wire BUS
- Up to 4 telephones/monitors per apartment (master, slave 1, slave 2 and slave 3).
- Up to 32 apartments/telephones per installation.
- Completely private conversation.
- Call volume control (maximum, medium and mute).
- Input for calls from the apartment's door.
- Call repeater output.
- Different ring tones indicate the origin of the call: door panel, intercom and apartment door.
- Lock release
1 activation
push button
.
-
Intercom/lock release
2 / activation light function "stairs light" (it requires of SAR-GB2 & SAR-12/24
Note:The light function only with T562 Telephones with V.03 or later.
modules)
push button
.
-
Push button for setting ring tones (inside the telephone)
- Dip switches for setting the telephone address (call code), master/slave, end of line and activating the
"doctor mode" (inside the telephone).

SYSTEM OPERATION

- To make a call the visitor should press the button corresponding to the desired apartment; an
audible tone indicates that the call is being made and the
vocal synthesis is
enabled
the
message
progress. At this moment the apartment's telephone(s) receive(s) the call. During the call the
visitor can correct his call by pressing a push button corresponding to a different apartment, in
which case the original call is cancelled.
- The call lasts for 40 seconds. If the call is not answered within 40 seconds, the
and the channel will be freed.
- To establish communication, lift the handset of any telephone in the apartment. The door panel LED
will turn on. If the vocal synthesis is enabled the message "you can speak now" will be heard confiming
the communication is activated
- The communication will last for one and a half minutes or until the handset is replaced. When
communication has finished the
and LEDs will turn off and the channel will be freed. If the
vocal synthesis is
enabled
the
message
panel confirming the communication has finished.
- To open the door, press the
push button (to open the second door, if there is one, press the
....... push button) during the call or communication processes: one press will activate the lock
release for five seconds and the
door panel
synthesis is
enabled
the
message
"door
- The descriptions of the function push buttons are found on page 3.
( ) For further information see the "T562 GB2 (code 50121599)" user manual.
*
https://doc.golmar.es/search/manual/50121599
installation.
away from any other
place without risk of drop or water projections
.
without polarity
).
.
door panel
LED
will turn on. If the
"call
is in progress
" will
be heard confirming the call is in
LED will turn off
"c
ommunication is finished
" will
be heard in the door
LED will also turn on during this time. If the vocal
is
open" will be
heard
on the door panel.
2
T562 G 2
B
TELEPHONE DESCRIPTION
( )
*
Descrip
tion
:
.
a.
Handset.
b.
Speaker grille.
c.
Microphone hole.
d.
Subjection hole.
e.
Telephone cord connectors.
Function push buttons:
Activates lock release 1 during the call reception and communication processes.
Activates lock release 2 during the call reception and communication processes.
During standby:
-
With the handset lifted it enables intercom functionality
- With the handset on the craddle it enables light function (it requires SAR-GB2 & SAR-12/24 modules).
Description of connection terminals:
L1 L2
L1 L2
,
:
BUS
connection.
_
HZ ,
:
Door bell push button connection.
_
SA , :
Call repeater connection, (SAR-12/24).
(12V c/50mA m xim
d
( )
Description of dip switch and setting of telephone address (code):
*
Dip1
to
Dip5:
Set the telephone address (addresses 0 to 31).
Dip6
and
Dip7:
Leave
Switches set to OFF have a value of zero.
The values of the switches set to ON are shown in the enclosed chart.
The telephone code will be the sum of the values of the switches set to ON.
Value chart
Switch number: 1
Value ON:
Dip8
and
Dip9:
Set the telephone as master/slave. Dip8 and Dip9 OFF, master; Dip8 ON and Dip9 OFF, slave 1;
Dip8 OFF and Dip9 ON, slave 2; Dip8 and Dip9 ON, slave 3.
Dip10:
Leave
OFF.
Dip11: Sets the end of line It should always be set to OFF in installations with only telephones. In installations with
monitors and telephones in the same apartment, set to ON for the telephones at which the BUS cable ends, and
set to OFF for intermediate telephones.
Dip12:
Setting this to OFF makes the volume control's OFF position function as mute .
Setting this to ON makes the volume control's OFF position function as doctor mode .
( ) For further information see the
*
https://doc.golmar.es/search/manual/50121599
TELEPHONE
b
d
a
c
e
f.
Lock release push button.
g.
Hook switch.
h.
Auxiliary function push button.
i.
Volume control.
.
Call volume control:
_
_
HZ
SA
The telephone has a call
volume control which can
be set to maximum, medium
or mute.
a
um
).
OFF.
ON
2
3
4
5
1
2
4
8 16
1
2
E
xample
: 0 + 0+4+0+16 = 20
.
"T562 GB2 (c
ode
. 50121599)"
3
f
h
i
g
e
MAX
OFF
3
4
5
6
7
8
9 10 11 12
"
"
"
"
user manual
.
Tabla de contenido
loading

Este manual también es adecuado para:

50121599

Tabla de contenido