English
Press the [ZERO] button repeatedly until SPREAD appears on the display.
Press the [TARE] button; PULSES appears on the display.
If you use the speed sensor, determine the number of pulses by driving a 100 m distance. In doing so,
unplug the operating position sensor.
If you use the adapter cable to the signal socket or the GPS receiver, you must normally enter 406
pulses. Adjust the displayed speed with the display on your towing vehicle and correct the value if
necessary.
Enter the number of pulses on the display with the numeric keypad and confirm with the <Ok> key.
Use the [TARE] key to move to the next WIDTH parameter.
Use the numeric keypad to enter the working width in m and confirm with the <Ok> key.
Press the [ZERO] button repeatedly until END appears on the display.
Press [TARE], and the settings will be saved; the display will restart.
9
Zero digits
The [ZERO] button is used to reset the zero point of the display.
10
Standard weighing process
Load your device and read the weight.
11
Display of application rate
After driving away, press the [f1] key. The amount per ha is now displayed every 10 seconds.
The calculation always takes place from the starting point and becomes more and more exact over time.
When the working sensor closes at the pre-processing, the calculation will be interrupted and will then
resume again.
If you change the speed or change the device setting, you must start a new calculation and press [f1]
again.
12
Calibration of the weighing display
If you operate the AGRETO three-point scale vertically or hanging only slightly forward or backwards, the
factory calibration is correct, and the scales are ready for immediate use. If this is not possible, the weighing
display should be calibrated for the usage situation of the scales.
As calibration determines the accuracy of the scale, these steps should be performed only if necessary and
with the utmost care!
Every new calibration replaces the existing one. Proceed as follows:
Place your vehicle on a flat surface.
Bring the attachment unit into the working position without loading.
Press and hold the rightmost (F3) and the leftmost (small) key on the weighing display simultaneously
until the calibration sequence starts.
Wait until the display shows the word GEN.OPT.
Press the [ZERO] button twice; SCALE will appear on the display.
Press the [TARE] button 3x; CAL will appear on the display.
Press the [SELECT] key; ZERO will appear on the display.
Press the [OK] button twice, and "Z in P" will appear on the lower display. Now the zero point will be set.
Wait until "Done" appears on the bottom display.
Press the [Ok] button, and ZERO will appear on the display.
Press the [SELECT] key; SPAN will appear on the display.