USE
11
I 1 I SANICOM
2 is designed to evacuate effluent from small
®
private or commercial units. Any other application of the product may
render the guarantee void. Never use it for paper towels, condoms or
sanitary items, oils, solvents, waste products, acids, bases, other liquids
that could cause an explosion, corrosive products, etc.
I 2 I WARNING
In the event of a power failure, turn off all water flowing into appliances
connected to SANICOM
2.
®
I 3 I Do not install or use the unit in an area presenting risks of explosion.
MAINTENANCE
12
Visually check that the collection station is operating properly at least
once every month and have it checked regularly (annually) by qualified
personnel. However, if there are any technical issues, ask your after sales
supporting service for advice.
GUARANTEE
13
SANICOM
2 is guaranteed for two years for parts and labour provided it is
®
both installed and used in accordance with the current instructions.
ALARM (as an option)
14
ATTENTION
The alarm module is powered at 230V. Attach the module to the wall
before connecting the device to the power supply. If the water level inside
the device is abnormally high: the red LED lights up + the buzzer sounds. If
the problem stops, the LED and the buzzer are deactivated.
OPERATION OF REMOTE UNIT
15
I 1 I GENERAL ALARMS
Level alarm
If the water level in the appliance is abnormally high:
triggering of siren + lighting of red alarm LED
+ starting of the other motor 3 seconds later
Time alarm
If one of the 2 motors runs for more than 1 minute:
triggering of siren + lighting of red alarm LED
+ starting of the other motor 3 seconds later
Mains alarm
In the event of a power cut (or when the appliance is disconnected):
triggering of siren + lighting of red alarm LED
+ flashing of the yellow mains LED
I 2 I GENERAL ALARM RESET
If the issue that caused one of the above alarms to trigger appears, the siren
will stop but the red alarm LED will stay on to memorise the fact that the
system encountered a problem (flashing lamp if the source of the alarm was
the alarm pressure switch and if the level pressure switch is defective). One of
the two buttons of the keyboard will stop the siren in all cases but will not turn
off the red LED unless the issue which caused the alarm to trip has been dealt
with. This is a way of avoiding the system being forgotten by mistake.
"Mains" LED
"Alarm" LED
"Motor 1" forced operation
"Motor 2" forced operation
13