Optional Surface Mounting (continued)
3
Locking the fixture to ceiling
With each fixture installation, insert additional
■
screw in ceiling opposite screw installed in
Church Key hole. This will prevent the fixture
from accidently sliding of screw mounting.
Screw
Screw
Please check with your local inspector to insure this mounting
method meets local requirements.
Care & Cleaning
CAUTION: Before attempting to clean the fixture,
disconnect the power to the fixture by turning the breaker
off or removing the fuse from the fuse box.
Your fixture is made from quality materials that will last many years with minimum care. You may want to
periodically clean the diffuser, or interior of the fixture using a mild, non-abrasive glass cleaner and a soft cloth.
DO NOT use solvents, or cleaners containing abrasive agents. When cleaning the inside of the fixture, make sure
you have the power turned off, and do not spray liquid cleaner directly onto the LEDs, LED driver or wiring.
Troubleshooting
Minor problems often can be fixed without the help of an electrician.
WARNING: Before doing any work on the fixture,
shut off power supply at the circuit panel to avoid
electrical shock.
Problem
The fixture does not light.
Screw
Possible Cause
The power is off.
There is a bad wire connection.
The switch is defective.
8
Screw
Check if power supply is on.
Check the wiring.
Test or replace the switch.
Corrective Action