adjusting the Motion sensor
FACTORY SETTINGS
□ Detection Area: Factory set at 75%
□ Hold Time: Factory set at 5 Minutes
□ Daylight Sensor: Factory set at Photocell Disabled
Motion Sensor
Detection Area
DIP 1
DIP 2
DIP 3
n
75%
ADjUSTMENT OPTIONS
Detection area
□ The motion detection area can
be adjusted by selecting the
combination of settings on the
DIP switches for the desired
motion detection area.
Hold-time
□ Hold-time is the time period the light will remain on after the
person has left the detected area. The amount of time the light
remains on can be adjusted by selecting the combination of
settings on the DIP switches for the desired hold-time.
Daylight sensor
□ The daylight threshold can be adjusted by selecting the
combination of settings on the DIP switches to determine the level
of darkness when the light will turn on automatically.
Care and Cleaning
CaUTiOn: Before attempting to clean the fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from
the fuse box.
□ Clean the fixture with a soft, dry cloth.
□ Do not use cleaners with chemicals, solvents, or harsh abrasives.
□ Do not use liquid cleaner on the LEDs, LED driver, or wiring inside the light fixture.
Daylight Sensor
Hold-time
Light Level
DIP 4
DIP 5
DIP 6
n
n
5 minutes
Disable
Detection Area
DIP 1
I
n
II
n
III
IV
LEDs
n
DIP Switches
Coverage By Install Height
DIP 2
10 ft. Ceiling
100%
43 ft. x 10 ft.
n
75%
36 ft. x 10 ft.
50%
26 ft. x 10 ft.
n
10%
7 ft. x 10 ft.
n
I
II
III
IV
I
II
III
IV
8
Motion Sensor
9 ft. Ceiling
8 ft. Ceiling
40 ft. x 9 ft.
39 ft. x 8 ft.
34 ft. x 9 ft.
33 ft. x 8 ft.
23 ft. x 9 ft.
23 ft. x 8 ft.
7 ft. x 9 ft.
7 ft. x 8 ft.
DIP 3 DIP 4
5 sec.
n
n
90 sec.
n
5 min.
n
15 min.
DIP 5 DIP 6
Disable
n
n
50 lux.
n
10 lux.
n
2 lux.
Driver
Housing (A)
I - 100%
II - 75%
III - 50%
IV - 10%
I - 5 sec.
II - 90 sec.
III - 5 min.
IV - 15 min.
I - Disable
II - 50 lux.
III - 10 lux.
IV - 2 lux.