POINT B - SETTINGS
DIP 1
(ON) MOTORS ROTATION DIRECTION CHECK (See Point C)
DIP 2
(ON) - setting the times (point D)
DIP 2-1
setting the pedestrian opening times (point E)
DIP 1-2
save/delete radio control codes for total opening (point F)
DIP 1-3
save/delete radio codes for pedestrian opening (point G)
DIP 1-2-3 save/delete radio codes for relay r-aux command (point H)
DIP SWITCHES CONTROL
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
DIP 7
Photocells AUTO-TEST activation (ON-activated).
DIP 8
Electric lock activation (ON-activated)
DIP 9
Electric lock pulse release (ON-activated)
DIP 10
Motors manual release facilitation (ON-activated)
DIP 11
Electric lock pulse engagement (ON-activated)
DIP 12
Selection of 1 or 2 motor operation (by factory OFF 2 motors)
DIP 13
Activate the radio system SUN (ON) - SUN-PRO (OFF)
DIP 14
Timed operation (OFF) - Operation with limit switches (ON)
DIP 15
Slowdown (ON - activated)
DIP 16
Contactors management (ON - activated)
DIP 17
Encoder management (ON - activated)
TYPE OF MOTOR
KING EVO
KING EVO L
KING EVO ICE
KING EVO L ICE
KING EVO 120V
KING EVO L 120V
TORQUE TRIMMER - Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer which varies the output
voltage to the head/s of the motor/s (turn clockwise to increase torque).
This torque control is activated after 2 s form any manoeuvre begging, whereas the motor is
turned on at full power to guarantee the starting at the manoeuvre begging.
PAY ATTENTION: IF THE TORQUE TRIMMER SETTING IS CHANGED, IT IS PREFERABLE TO REPEAT THE
TIME PROGRAMMING.
LOW SPEED TRIMMER - Electronic regulator for low speed on approach
Adjustment of low speed is carried out using the LOW SPEED Trimmer which varies the output
voltage to the head/s of the motor/s (turn clockwise to increase speed). Adjustment is carried
out to establish the correct speed at the completion of opening and closing, depending on the
structure of the gate, or if there is any light friction that could compromise the correct working
of the system. The low speed is activated (DIP 15 ON) when the gate leaf is 0.50-0.60 meters
away from the complete close or open position.
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN openings
by factory NOT ACTIVATED and LED DL11 OFF
(trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic
closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11 ON
(trimmer rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a
maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2 s to a
maximum of 30 seconds.
Ex: With TCA trimmer setted halfway, you will have 1 minute pause after the total opening and
15 s of pause after the pedestrian opening prior to have the auto-close of the gate.
R-AUX - AUXILIARY RELAY CONTACT (NO)
By factory this relay is set as courtesy light (max 700 W - 3 A - 230 Vac) to operate 3 minutes
at each command, with time renewed at each command.
You can activate the R-AUX contact by TRANSMITTER by performing the memorization
procedure described in point H.
LED WARNING
DL1
PROG programming activated
CODE
DIP 18
DIP 19
AA14050
AA14070
OFF
ON
AA14060
AA14075
AA14052
ON
OFF
AA14072
(red)
DL2
M1 - gate opening
DL3
M1 - gate closing
DL4
M2 - gate opening
DL5
M2 - gate closing
DL6
STOP command (NC)
DL7
PHOTO 1 contact (NC)
DL8
PHOTO 2 contact (NC)
DL9
EDGE 1 contact (NC)
DL10
EDGE 2 contact (NC)
DL11
TCA - automatic closure time enabled
DL12
Remotes programming enabled
DL13
Card managed by APP
DL14
Opening limit switch LSO M1/ENC
DL15
Closing limit switch LSC M1
DL16
Opening limit switch LSO M2/ENC
DL17
Closing limit switch LSC M2
DL18
PROG and RADIO (on MOLEX connector) commands
B.I.O
Clock command (NO)
PED.
Pedestrian command (NO)
START Single impulse command (NO)
CLOSE CLOSE command (NO)
OPEN OPEN command (NO)
DIP 20
C - MOTOR/S ROTATIONAL DIRECTION CONTROL
1 - Unlock the operators with the Manual Release - swing open the leaves about halfway and
lock again the operators.
2 - Turn DIP 1 to ON position The red LED DL1 starts blinking.
OFF
3 - Press the PROG button and hold it - When GREEN LEDS DL2 and DL4 are on, the gate leaves are
opening (with a phase shift of 2 s). Check the leaves swinging and the opening mechanical
stopper position (movement is now performed in "man present" mode, open-close-open-
etc.).
ON
If any of the leaf closes instead of opening, release PROG button, turn OFF the main power
and reverse the two phase wires (V1/2 and W1/2) of the relevant motor/s.
4 - Press the PROG button and hold it to CLOSE completely the gate. When RED LEDS DL5 and DL3
are on, the gate leaves are closing (with a phase shift of 2 s). Check leaves swinging and the
closing mechanical stopper position.
5 - After 2 s motor starting and for the next 10 s motor working, the torque controls
automatically activated. Set the motor torque by the TORQUE Trimmer/s which varies the
output voltage to the motor/s (turn clockwise to increase the torque).
6 - After other 10 s motor working, the low speed controls automatically activated (DIP 15 ON).
Set the motor low speed by the LOW SPEED Trimmer to select the gate leaf low speed in
approaching.
7 - Close completely the gate.
8 - Turn DIP 1 to OFF position, LED DL1 turns OFF.
During Point C procedure, safety devices (photocells and safetystrip) are not active.
D - TIMES PROGRAMMING
N.B.: DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND THEIR
INTERVENTION STOPS PROGRAMMING (THE DL1 LED FROM FLASHING REMAINS
ON FIXED) AND THE BUZZER PLAYS FOR 10 s. TO REPEAT THE PROGRAMMING
PROCEDURE POSITION THE DIP 1 AND DIP 2 TO OFF, CLOSE THE GATE THROUGH
PROCEDURE «CHECKING THE DIRECTION OF MOTOR ROTATION» AND REPEAT THE
PROGRAMMING OF THE CHOICE.
N.B.: The deceleration is automatically determined during the times programming,
and is activated about 50÷60 cm before the end of opening or end of closing.
- FOR 2 MOTORS - DIP 12 OFF
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
4 - Reached the mechanical stopper in opening => after 1 s press the PROG./RADIO/OPEN/
START button to stop M1 and open M2.
5 - When the mechanical opening stopper has been reached => after 1 s press the PROG./
RADIO/OPEN/START button => M2 stops.
6 - Press the PROG./RADIO/OPEN/START button => M2 closes.
7 - After a few seconds press the PROG./RADIO/OPEN/START button => M1 closes and
determine the phase displacement between M2 and M1.
At the same time the LED DL1 will stop flashing, signaling the exit from the programming
procedure.
From this moment the safety devices or other gate commands will work normally (inversions,
40