INSTALLATION INSTRUCTIONS

After making sure nothing is missing in the
packaging, fit the 2 missing feet and position
the machine in the housing provided.
Connect the water cleaner inlet
water supply point; connect the cleaner outlet
pipe
to the pump inlet; next connect the
supply pipe
to the pump outlet. Finally fit
the drain pipe
provided to the connection
point underneath the machine bed and secure
the seal using the special clip.
Position the cup-warming plate, the cup-
warming strip, the dome, the drain trays and
finally the eagle in the housings provided.
Next make sure the machine is level by means
of the adjustment feet.
Make sure the power supply system is compat-
ible with the details shown on the machine
identification plate.
Connect the power cable
machine to the pump and the power plug
up to the
to a properly earthed power socket.
Avoid any bends and blockages in the pipes.
Make sure the drain is free and, if the power
cable provided is inadequate, use another with
the same cross section.
The machine must always be protected by
means of an automatic switch of adequate
power.
The company disclaims liability for any damage
to things or injury to persons caused by failure
to observe the applicable safety regulations.
STARTING UP
Turn the master switch from position 0 to posi-
tion 1 so the boiler can correctly fill up. To
coming from the
reach suitable filling level, the machine may
have to be switched off several times and the
master switch returned to position
1. The switch can only be moved to position 2
once maximum level has been reached.
After about 20 minutes, the machine will have
reached operating pressure. This is indicated on
the double-scale pressure gauge.
To change the operating pressure of the boiler
(and consequently the temperature) according
to the various requirements or characteristics
of the coffee used, simply lift the cup-warming
plate and adjust the pressure switch screw;
when this is turned clockwise, the pressure
drops and vice versa (the tested machine is nor-
mally set at about 0.8 - 0.9 bar).