05-707
Step 1 (Setting the switch principle)
OK
Resistive loads
capacitive loads
(electronic transformers)
Mixed loads
Go to step 2
Step 2 (Choice of remote control)
Push button control (see 4.3)
Without memory (see 4.9)
With memory (see 4.9)
Switch on power supply
Switch on power supply
Briefly press push button
Briefly press push button
Dim to max. light intensity
Press briefly to switch off
OK
nv Niko sa
Overvoltage protection
Switch off power
supply
Switch to phase control
Switch on power supply
OK
Inductive loads
(ferromagnetic
transformers)
Go to step 2
Dim up to 20%
Press long to ⇑⇓
OK
Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 760 14 70 — fax +32 3 777 71 20 — e-mail:
[email protected] — www.niko.be
Switch off power supply
Only connect mains and load
(not the remote control)
Switch to reverse phase control
Switch on power supply
Overload or short-circuit
Switch off power
supply
Reduce load or
restore short-circuit
Switch power supply on
Overload
Switch off power
supply
Reduce load
Switch on power supply
Switch off power supply
Connect the control signal
Control choice
Analog control (see 3.1)
Automatic selection (see 4.5)
Switch on power supply
Wait for 10s.
Operate control
Dimmer follows
OK
Dimmer not connected to load
Switch off power supply
Switch on power supply
Manual selection (see 4.6)
0-10V analog
(see 4.7)
Switch on power
supply
Dimmer does not follow
Switch off power
supply
Change places of '+' and '-'
Restart procedure
Connect the load
1-10V analog
(see 4.8)
Switch on power
supply
Use electronic
potentiometer
Dimmer follows
OK
PM005-70700R07154