05-707
7. TEST
The dimmer can permanently operate at max. with a simple setting:
- bipolarly disconnect the 230V power supply;
- switch DIP switch 4 to OFF (manual selection);
- switch DIP switch 2 to OFF (analog control);
- switch DIP switch 3 to OFF (1-10V);
- disconnect both 10V control wires;
- connect the 230V power supply;
The dimmer now switches to max. without requiring a control signal
Warning: the dimmers are never electrically separated from the mains
by operating the control. All components, incl. the lamps, therefore remain
live even when the light is "off".
Signals that are sent via the mains, can interfere with the operation of the
dimmer. This interference only occurs if this signal is sent via the mains.
8. COOLING
Cooling is essential for reliable and safe operation.
The dimmer produces approx. 1.2% heat vs the connected load.
E.g.: 500W lighting = 6W dissipation
Provide sufficient cool air circulation with regard to the total dissipated
power. If the natural air circulation is limited, a fan must be provided in
the cabinet or in the room.
Nominal ambient temperature: 20°C
9. INTERFERENCE SUPPRESSION
Interference over the power supply cables: the degree of interference sup-
pression complies to the European (EN55015) and international (CISPR15)
standards.
10. TECHNICAL DATA
power supply: 230V~ 50Hz
dimensions: (H x W x D) 89 x 70 x 54.5mm
weight: 0.216kg
min. load: 35W or 2 electronic transformers
max. load: see load table (fig. 3)
Important: the max. load mainly depends on the ambient temperature
(fig. 3).
Special remarks with regard to inductive loads:
- ferromagnetic (wound) transformers have to be loaded for min. 75%;
- the consumption of ferromagnetic transformers must be increased by
the cosine phi;
- in case toroidal core transformers are used, the max. load is limited to
450W.
11. MAINTENANCE
These appliances are suitable for use in the following conditions:
- an ambient temperature of 35°C;
- a environment with a non-condensing atmospheric humidity;
- a mains voltage of 230V.
A regular check of at least the following is recommended after the power
supply has been switched off completely:
- pressure of the screw terminals;
- ventilation.
12.GUARANTEE PROVISIONS
- Period of guarantee: 2 years from date of delivery. The delivery date is
the invoice date of purchase of the product by the consumer. If there is
no invoice, the date of production applies.
- The consumer is obliged to inform Niko in writing about the defect,
within two months after stating the defect.
- In case of a failure to conform, the consumer has the right to a repair
or replacement (decided by Niko) free of charge.
- Niko cannot be held liable for a defect or damage as a result of an incorrect
installation, improper or careless use or wrong usage or transformation
of the goods.
- The compulsory regulations of the national legislation concerning the
sales of consumer goods and the protection of the consumers in the
countries where Niko sells, directly or via sister or daughter companies,
chain stores, distributors, agents or permanent sales representatives,
take priority over the rules and regulations mentioned above.
nv Niko sa
fig.1
fig.2
fig.3
fig.4
Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 760 14 70 — fax +32 3 777 71 20 — e-mail:
[email protected] — www.niko.be
I
0
100%
4s.
2s.
min.
0%
Push button control 05-707
Drukknopbediening 05-707
With memory: DIP Switch 2 to ON
Met geheugen: DIP-switch 2 op ON
Press briefly (<0,4s.) = ON / OFF
kort drukken (<0,4s.) = ON / OFF
ON /OFF
Press long (>0,4s.) = UP / DOWN
lang drukken (>0,4s.) = UP / DOWN
Dimming UP: stop at 100%
Bij stijgen: stop op 100%
Dimming DOWN: stop for 2s. at min. level then dim UP
Bij dalen, stop 2s. op min., daarna stijgen.
Press repeatedly: reverse dim direction.
Herhaaldelijk drukken keert de dimrichting om.
UP / DOWN
I
0
100%
min.
0%
4s.
Push button control 05-707
Drukknopbediening 05-707
Without memory: DIP Switch 2 to ON
Zonder geheugen: DIP-switch 2 op ON
Press briefly (<0,4s.) = ON / OFF
kort drukken (<0,4s.) = ON / OFF
ON /OFF
Press long (>0,4s.) = UP / DOWN
lang drukken (>0,4s.) = UP / DOWN
Dimming UP: stop at 100%
Bij stijgen: stop op 100%
Dimming DOWN: stop for 2s. at min. level then dim UP
Bij dalen, stop 2s. op min., daarna stijgen.
Press repeatedly: reverse dim direction.
UP / DOWN
Herhaaldelijk drukken keert de dimrichting om.
W
600
500
400
300
200
100
a
t
10
20
ambiante temperature
Omgevingstemperatuur
Overcurrent protection
(Short-circuit or overload)
Overvoltage protection (Reverse phase
control instead of phase control or
defective load or surges on the mains)
DC or thermal protection
I
U
HAL.12 - 24V
HAL.12 - 24V
0 - 10V
0 - 10V
ON
ON
OFF
OFF
1
2
3
4
1
2
3
Manually setting the
Phase control (inductive loads)
control signal to 0-10V
1 OFF = Reverse phase control
3 OFF = Analog 1-10V
(res. + cap.)
DIP Switch 4 to ON
DIP-switch 4 op ON
2s.
DIP Switch 4 to OFF
DIP-switch 4 op OFF
max.
MAX.
load
Belasting
memo
35°C = 600W
40°C = 550W
45°C = 500W
50°C = 450W
min.
MIN.
load
Belasting
°C
30
40
50
ON
Automatic selection of
control signal (0-10V or 1-10V)
OFF
1
2
3
4
4 OFF = Manual selection
ON
Push button control
OFF
2 OFF = Analog control
1
2
3
4
I
U
ON
Push button control
with memory
OFF
4 OFF = Without memory
1
2
3
4
1 Reverse phase control
ON
2 Analog control
4
3 Manually setting the
control signal to 1-10V
OFF
4 Manual signal selection
1
2
3
4
(0-10V or 1-10V)
PM005-70700R07154