Installing The Sfp+ Optics; Supply Power And Power Up The System - Dell Networking S3048 Guía De Inicio

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CAUTION: DO NOT mix airflow directions. All fans must use the same
airflow direction (I/O to Utility or Utility to I/O).
CAUTION: Check the fans at six-month intervals and replace them as
necessary. To accurately determine replacement intervals, regularly
monitor the speeds of the cooling fans.

Installing the SFP+ Optics

The S3048–ON has four small form-factor pluggable plus (SFP+) optical
ports.
For a list of supported optics, refer to the S3048–ON data sheet at
www.dell.com or contact your Dell Networking representative.
CAUTION: ESD damage can occur if the components are mishandled.
Always wear an ESD-preventive wrist or heel ground strap when
handling the S3048–ON and its components.
WARNING: When working with optical fibers, follow all the warning
labels and always wear eye protection. Never look directly into the end
of a terminated or unterminated fiber or connector as it may cause eye
damage.
1.
Position the optic so it is in the correct position. The optic has a key that
prevents it from being inserted incorrectly.
2.
Insert the optic into the port until it gently snaps into place.
NOTE: When you cable the ports, be sure not to interfere with the
airflow from the small vent holes above and below the ports.

Supply Power and Power Up the System

Supply power to the S3048–ON after the chassis is mounted in a rack or
cabinet.
Dell Networking recommends re-inspecting your system prior to powering
up. Verify that:
The equipment is properly secured to the rack.
The equipment rack is properly mounted and grounded.
The ambient temperature around the unit (which may be higher than the
room temperature) is within the limits specified for the S3048–ON.
There is sufficient airflow around the unit.
17
Tabla de contenido
loading

Este manual también es adecuado para:

E14wE14w001

Tabla de contenido