Automatic operation
In the automatic mode, the level switch automatically
controls the pumping operations. The pump switches on
or off when the fluid level reaches the height that has
been set.
Ensure that the level sensor is not obstructed in any
way.
Illustration
In automatic operation, set the required switching
height by clamping the level switch cable into the
stopper.
Open the locking tap to remove water (arrow vertical).
Insert the mains plug into the socket.
Manual operation
In manual operations the pump remains switched on
continuously.
Illustration
In manual operations mode, align the level sensor
upward (cable pointing downward). Tip: Push the
cable of the level sensor like a loop through the
handle.
Open the locking tap to remove water (arrow vertical).
Insert the mains plug into the socket.
NOTICE
Dry running leads to increased wear and tear; do not
leave the pump unattended during manual operation.
Switch off the pump within 3 minutes of dry running.
Finish operation
NOTICE
Soiling can deposit and lead to malfunctions.
Rinse the pump with clean water after use.
This especially applies after pumping chlorinated
water or other liquids that leave residue.
Rotate the housing with the level switch in the ar-
row direction "OFF". The pump will turn off.
Disconnect the main plug from the socket.
Maintenance
The pump is maintenace-free.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance during transport (see Spec-
ifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle
secure it from slipping.
10
Transport
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance when selecting a storage lo-
cation for it (see Specifications).
Storing the Appliance
Illustration
Tip the drum edge holder forward and take out to-
ward the top.
Completely drain the pump and allow it to dry.
Store the appliance in a frost free area.
EN
– 2
Storage