4. MEMORY
4.1. Save Configuration:
- utomatic save: 30 minutes after the last button is
pressed, the current data will be stored in the
SM 8000 / SM-ST 8000
4.2. Restore Configuration:
stored in the unit to be recovered.
4.3. Save Configuration, Device to UCF 300:
enables the configuration stored to be saved with an
identifying name in one of the 26 memories of the
UCF 300.
4.4. Load Configuration, UCF 300 to Device:
recovers the data in one of the UCF 300's memories
for cloning on another unit SM 8000 / SM-ST 8000.
I
RF LEVEL DJUSTMENT
Remove the coaxial bridge from the RF channel
G
output of module 1 beside the power source.
djust the output level of this module to 90 dBµV.
G
Connect the 75
coaxial bridge again.
G
Taking the measurement at the SH or S C amplifier
G
output, adjust the levels of the other modules so that they
are equalised to the level of module 1, which has
already been adjusted.
djust the amplifier gain, taking into account its maximum
G
output level and the reduction according to the number
of the channels in the installation, as shown in Table 1.
Tab. 1
*Number of channels
2 4
Reduction of the
maximum output
0
3
level (dB)
* TV M modulation
- When there are both analog and digital channels,
the digital channels must be at least 10 dB lower than
the analog channels.
I
LED FUNCTIONS
Status LED:
G
Green: OK.
G
Yellow: Error
G
Red: Unit failure
G
Communication LED: Only for centralized programming
G
with MCU8000.
Stores current programming.
Enables the configuration
5
6
8 16 24 32 64
4
5
6
9 11 12 15
11