Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Installation Instructions
•
The fitting must be installed, flushed and tested after
the valid norms!
•
Important!* With water heaters of 5 liters the flow rate
at the mixer should not exceed 5 l/min.
•
In this case the flow rate must be reduced at the
isolation valve.
Technical Data
Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Symbol description
Operation (see page 37)
When the storage tank is being heated, the
spout will drip.
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
Water escaping in area of swivel
spout
Water escaping at the threaded
base
Water escaping bels ow handle
English
max. 1 MPa
0,1 – 0,5MPa
max. 80°C
65°C
max. 5 l/min
Cause
- Spray former calcified, dirty
- Filter at the isolation valves soils.
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Cartridge defective
Assembly see page 32
Do not use silicone containing acetic acid!
Maintenance (see page 38)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
When changing the spray former, it is
imperative to use one made for this type of
mixer.
Dimensions (see page 35)
Spare parts (see page 36)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Cleaning
Cleaning recommendations, see enclosed
brochure.
Remedy
- Clean spray former, exchanging if
necessary
- Clean the filter / exchange filter
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Exchange cartridge