Clean The Spark Plug - Urrea GG835A Manual De Usuario Y Garantía

Generador a gasolina
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fuel valve
Strainer
Sedimentation glass

CLEAN THE SPARK PLUG

1.
Remove the spark plug cap.
2.
Clean the spark plug base.
3.
Remove the spark plug with the spark plug
socket spanner.
4.
Inspect the spark plug insulator visually for
damage. If it is damaged, replace a new
one.
5.
Measure the spark plug clearance with a
feeler gauge. The clearance should be kept
between 0.70 and 0.80mm.
6.
Inspect if the washer of the spark plug is in
good condition.
7.
Reinstall the spark plug and tighten it with
the spark plug socket spanner. Press down
the washer of the spark plug and place the
spark plug cap.
VALVE CLEARANCE (SHOULD BE CONDUCTED
BY A PROFESSIONAL)
Feeler gauge
Remove the cylinder cover and measure the
valve clearance with the feeler gauge. The
clearances are 0.1mm for the inlet valve and
0.15mm for the outlet valve.
Sedimentation glass
O-type seal ring
E N G L I S H •
The environmental condition required to
operate the generator:
Suitable temperature: -15ºC-40ºC.
Suitable humidity: lower than 95%.
Suitable altitude: under 1,000 meters (The
power load should be reduced where the
generator is used at altitudes greater than
1000 meters.)
The generator unit can only be loaded to the
rated power under the specified environment
conditions. If the environment conditions are
inconsistent with the above standards, or if the
cooling conditions of the engine and generator
unit are poor; for example, when operating
in enclosed areas, it is necessary to reduce the
power load. It is also necessary to reduce the
power load when the temperature, altitude or
relative humidity exceed the standards.
If the generator does not work properly
in optimal conditions, please take to the
nearby dealer or after-sales service center for
inspection.
U s er 's M an u al
21
Tabla de contenido
loading

Este manual también es adecuado para:

Gg870Gg890

Tabla de contenido