Replace high pressure nozzle
with steam nozzle, order nr. 4.766-
024.0.
Set the operating pressure on the
appliance to the minimum value.
Set temperature regulator to min.
100 °C.
DANGER
Scalding danger!
We recommend the following cleaning
temperatures:
– De-preserve, contaminations con-
taining strong fat contents
100 -110 °C
– De-frosting of surcharge substanc-
es, partially facade cleaning
up to 140 °C
AFTER EACH USE
DANGER
Danger of scalding by hot water. After
the operation with hot water or steam,
the device must be operated with
openend gun with cold water for at least
two minutes.
After operation with detergent
Set dosing value for detergent to "0".
Set the appliance switch to "I".
Open the hand spray gun and rinse
the appliance for at least 1 minute.
Turn off the appliance.
Set the appliance switch to "0".
Shut off water supply.
Turn on pump shortly (appr. 5 sec-
onds) with device switch.
Pull main plug out of socket with dry
hands only.
14
English
Remove water connection.
Activate hand spray gun until device
is pressure less.
Secure hand spray gun, Figure 5
(A).
Lock in the steel pipe into the holder
of the appliance hood.
Roll up high pressure hose and elec-
trical conduit and hang them into the
respective holders.
Note
Do not twist high pressure hose and
electrical conduit.
WARNING
Frost will destroy the not completely wa-
ter drained device.
Store in a frost free area.
If the device is connected to a chimney,
the following must be observed:
WARNING
Threat of damage by penetrating cold
air through the chimney.
Disconnect device from chimney
when outside temperature drops be-
low 0 °C.
If it is not possible to store frost free,
shut down device.
IDLING
For longer work breaks or if a frost free
storage is not possible:
Dump water and flush device with
anti-freeze agent.
Empty detergent tank.
Dump water
Screw off water supply hose and
high pressure hose.