MULTIJET PRO
3.2 - ULTRA CLEANER BIO
Always use Ultra Cleaner Bio in the injector cleaning processes, his formula contains biodegradable surface-
acting, scale-removing and humectant agents that together unclog and remove deeper dirt.
How to use:
Dilute the quantity of the Ultra Cleaner Bio to be used in 3 equal parts of water.
E.g.: 200ml of Ultra Cleaner Bio for 600ml of water.
+
=
600ml of water
200ml of Ultra Cleaner Bio
800ml of liquid ready for use
The Ultra Cleaner Bio must be changed when it becomes too contaminated. The life of this fluid depends on
the cares that precede the cleaning by ultrasound, such as:
- Perform the pre-cleaning in the injector, removing the excess dirt in the external parts.
- Keep the vat covered when not in use.
- Try to take to the vat parts with as little residue as possible from other fluids (gasoline, kerosene and others).
For this, before ultrasound cleaning, give the parts to be cleaned by compressed air.
3.3 - PRESSURE HOSE CONNECTION
Connect the hose and lock properly. Avoid accidents and waste test fluid.
Insert the connector until the end of the course.
Press the lock until the end of the course.
Ensure that the lock was inserted after the cam lock.