Troubleshooting Guide; Possible Cause - PUR PQC1FS Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide:

Problem
Water leaks between sump and
head
Water leaks at push-in connections
Water leaks at threaded fittings
Water has air bubbles and is cloudy Air in the system after installation
Water leak at thread fittings
Either no water flow or very slow
Water tastes bad or has an odor
Should service be required or you have any questions regarding how to use your PUR product, please contact Customer Service at:
1-877-447-4768 or [email protected]

Possible Cause

Loose connection of sump and head
O-rings missed or not in right position
Tubing is not pushing in all the way
Tubing end is not cut square
Tubing is cracked or scratched
Loose connection
Fitting not tightened
Inlet valve is closed
Filter cartridge has become clogged
Tubing is kinked
The filter is expended
Solution
Unlock the filter head assembly and re-install the housing.
Open sump to check the O-rings.
Push tubing in as far as it will go.
Push tubing out and recut to square.
Simply cut that portion away and reinsert tubing.
Tighten slightly more until leak stops. Do not over-tighten.
Will go away after water runs for a while.
Tighten fittings as necessary.
Turn on the valve.
Replace the filter cartridge.
Check the tubing and make smooth line.
Replace the filter cartridge.
8
Tabla de contenido
loading

Este manual también es adecuado para:

Pqc2fs

Tabla de contenido