Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Performance Data Sheet:

Note: Read this performance data and compare the capability of this system with your actual water treatment
needs. It is recommended that, before installing the system, you have your water supply tested to determine
your actual water treatment needs.
These systems conform to NSF/ANSI 53 and/or 42 for the specific performance claims as verified and substantiated by test data.
While testing was performed under standard laboratory conditions, actual performance may vary.
The PQC1FS system has been certified by NSF International according to NSF/ANSI 42 and CSA B483.1. The PQC2FS system has
been certified by NSF International according to NSF/ANSI 42, 53 and CSA B483.1 for the reduction of substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system as specified in NSF/ANSI 42 and 53.
PQC1FS with PQCCRB Filter
Substance
NSF Standard 42
Chlorine
Particulate Class III
Flow Rate =1 gpm (3.78 lpm)
PQC2FS with PQCSED and PQCCRBL Filters
Average Influent
Substance
Challenge Concentration
NSF Standard 42/53
Chlorine
2.0 mg/L ± 10%
Particulate Class I
pH 8.5
Lead
0.15 mg/L± 10%
pH 6.5
Cyst
≥ 50,000 /mL
Flow Rate = 0.5 gpm (1.9 lpm) Capacity = 500 gallons (1,890 L) or 6 months
Tested by NSF International according to NSF/ANSI Standard 42, 53 and CSA B483.1.
1
Manufactured and warranted by GHP Group Inc.
USA: 6440 W. Howard St. Niles, IL 60714-3302
Canada: 271 Massey Rd. Guelph, Ontario, N1K 1B2
9
Average Influent
Percent Reduction
Challenge
Concentration
2.0 mg/L ± 10%
10,000/mL
Capacity = 1,000 gallons (3,780 L) or 6 months
Percent Reduction
Requirement
≥ 50%
10,000/mL
≥ 85%
0.010mg/L
≥ 99.95%
Percent Reduction
Requirement
1
≥ 50%
91.8%
≥ 85%
99.9%
Percent Reduction
97.4%
99.6%
99.7%
99.7%
99.99%
1