Inground Spa Manual
3.4. ELECTRICAL CONNECTION
The main electricity cabinet is in charge of controlling all of the Spa's functions. Consult the
following manuals which explain in detail each of the connections to make and the cable cross
sections to use:
Operation Manual for Compact Kit for Public Use.
Installation and Operation Manual for Compact Kit for Private Use.
Once the connections specified in the above manuals are made, keeping the main circuit
breaker on the OFF position, connect the kit to the operation cabinet and in turn the operation
cabinet to the power supply, previously checking the voltage.
3.5. START UP
With the main circuit breaker on the OFF position, clean the Spa shell to avoid particles of
the works being absorbed and obstructing the components or circuits.
Open all the valves except the drainage.
a) Spas with Overflow and Balance Tank:
Open the Spa's filling valve and fill up the Spa until the water exceeds the S
balance tank by 5 to 8 cm.
Important: When you start up the filtering equipment for the first time, the water level of the
balance tank will decrease substantially. This is due to the fact that the piping between the
balance tank and the Spa, filter and pump is practically full of air.
b) Spas with Skimmer:
Fill up the Spa up to the line marked on the Skimmer. The water should never be below this
level.
Wait for 15 minutes and inspect all the connections to ensure there are no leaks.
Provide electrical power to the cabinet by switching on its main circuit breaker (ON position).
Start up the filter pump, the massage pump and the air pump and check that there are no leaks
in the pipes and connection elements after 30 minutes of operation.
Stop the filter pump and fill the water filter up to half, and then subsequently fill with sand (the
type of sand to be used is specified in the Filter Manual annexed to the Compact Kit).
Place the selector valve of the filter with the lever in the wash position. Manually activate the
filter pump; carry out a wash in the filter lasting approximately 2 minutes, stop the pump and set
the lever to the rinse position. Start up the pump again and rinse for approximately 15 seconds.
Stop the pump and change the lever to the filter position. Fill up the Spa once again.
Program the thermostat to the desired temperature. Read the Compact Kit manual. (Reaching
the desired temperature after filling up the Spa may take several hours).
Program the filter clock. (Read the Compact Kit Manual).
In the main electrical cabinet, activate the massage and heating switches. Set the filtering
switch to the desired position, and the Spa will start to function carrying out the filtering and
heating cycle.
Once these checks have been made, fill in the attached Warranty form and send it to the
manufacturer.
26
EN
level of the
MAX