PROGRAMMING PROCEDURE (Setting the programmer and the current sensor)
Attention! Before starting the barrier must be completely closed. Press the "SEL" button to move the barriere to the completely closed position.
•
Make sure that display "D" is off and LEDs "L4", "L5","L6", "L7", "L8" are all lit.
•
Open the "Standard wiring diagram" which is folded inside the last page of this manual and carry out the programming procedure.
D
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE PARAMETER
DEFINITION LETTER "d" WILL APPEAR
ON THE DISPLAY (STAGE "A")
AFTER SECOND THE DIGIT "" WILL APPEAR
(FIRST PROGRAMMING STEP). THIS NUMBER
CAN BE EITHER FLASHING OR FIXED
ACTIVE
FUNCTION
PRESS
Dynamic button
PROG
open-close
Note
PRESS SEL
Automatic
PRESS
reclosing
PROG
enabled
PRESS SEL
PRESS
Preflashing
PROG
enabled
PRESS SEL
Warning light
PRESS
output
PROG
fixed
PRESS SEL
Fixed
indicator light
PRESS
PROG
PRESS SEL
FTCI
PRESS
also active
PROG
during stop
Note 3
PRESS SEL
PRESS
SEL
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
...4... sec.
Important notes regarding the programmer settings
Note Travel direction inversion only during the closing stage.
Note 2 The indicator light flashes slowly during opening, quickly during closing;
... sec.
Note 3 If the photoelectric cells are in alarm and the barrier is blocked no movement
CURRENT SENSOR
The programmer checks the electrical input to the motor, detecting any eventual increase in
ACTIVE
effort above the normal operating limits and intervenes as an additional safety device.
FUNCTION
Dynamic button
open-stop
close-stop
Automatic
reclosing
excluded
Preflashing
excluded
Warning light
output
intermittent
Intermittent
indicator light
Note 2
FTCI
active only
during closing
PRESS
PROG
...20... sec.
remains lit when the boom is not completely closed and is off when the
boom is completely closed.
commands will be accepted (not even in the opening direction).
PRESSING THE "PROG" BUTTON WILL MOVE YOU TO
STAGE "B" SETTING THE CURRENT SENSOR. THE VALUES
RANGE FROM TO 3. THE DEFAULT VALUE IS 2
(THE VALUES OR 3 CAN APPEAR FIXED IF THE CURRENT
SENSOR HAS ALREADY BEEN SET)
ALTERNATING
ALTERNATING
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
SEL
PRESS
PROG
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
9
FIXED
VALUE
PRESS
PROG
FIXED
VALUE
PRESS
PROG
FIXED
VALUE
PRESS
PROG
PREMERE
SEL
...20... sec.
CONTINUE ON PAGE 0