14
PRESET
1. Preset mode
q The preset mode is available when PRESET button is pushed for more than 1 sec while DN-S5000 is in
Cue, pause or no disc mode.
w Turn the PARAMETERS knob to select the preset item.
e After selecting an item, push the PARAMETERS knob to select the preset data.
r To change other Preset items, repeat these steps.
t Push the PRESET, CUE or PLAY/PAUSE (
13
2. Preset items and data
The " *" mark next to the data indicates the default value.
(1)
AUTO CUE : Auto Cue level search on/off. (ON* / OFF)
(2)
PITCH RANGE : Select the playing pitch range when the power is turned on. (±4 / ±10* / ±16 / ±24%)
(3)
ALPHA-TRACK OUTPUT : Alpha-Track playback output destination. (Main out* / Alpha out)
(4)
PLATTER : Select whether or not the Platter is to rotate during playback. (Turn round* / Turn stop)
(5)
PLATTER MODE MEMO :
When the Platter mode (DRAG-S, BRAKE and ECHO) parameters, the source and the on/off setting
are stored, the stored data is set each time the power is turned on.
q To set the effect data, push the PARAMETERS knob and select " YES" .
• " Set OK?" flashes on the character display.
w Push the PARAMETERS knob again and select " OK" to execute setting the data.
e Once setting is completed, " Complete!" is displayed.
(6)
AUTO LOAD : Time for automatically loading disc. (OFF / 10 / 30 / 60* seconds)
(7)
EOM : Track end message start time. (OFF / 10* / 15 / 20 / 30 / 60 / 90 seconds)
(8)
DIGITAL OUT OUTPUT LEVEL : Select the digital out output level. (Normal* / – 6 dB Down)
NOTE: Use – 6dB if the playback output is clipped when the Main and Alpha-Tracks are played
simultaneously at the same position.
(9)
FADER START MODE: Select 2-line type (Cue and Play) or 1 line type (Play and Pause).
(Play /Cue* / Play/Pause)
(10) POWER ON PLAY : Playback starts when the power is turned on if a disc is loaded. (On / Off*)
(11) A3/4 MODE : Select the A3 and A4 button operating modes when the power is turned on.
(Sampler* / 4H/S / Alpha-Track H/S)
(12) SINGLE/CONTINUOUS : Select the play mode when the power is turned on. (Single* / Continuous)
(13) ELAPSED/REMAIN: Select the time mode when the power is turned on.
(Elapsed* / Remain)
(14) PROGRAM ALL CLEAR : Clear all program play data in the non-volatile memory.
q To clear the program, push the PARAMETERS knob and select " YES" .
• " Clear OK?" flashes on the character display.
w Push the PARAMETERS knob again and select " OK" to execute clearing the program.
" Prog. Clear" is displayed on the character display while data clearing.
e Once clearing is completed, " Complete!" is displayed.
(15) MEMO ALL CLEAR : Clear all MEMO data in the non-volatile memory.
q To clear all MEMO data, push the PARAMETERS knob and select " YES" .
• " Clear OK?" flashes on the character display.
w Push the PARAMETERS knob again and select " OK" to execute clearing all MEMO data.
• " Memo Clear" is displayed on the character display while clearing.
e Once clearing is completed, " Complete!" is displayed.
) button to exit from the Preset mode.
(16) MEMO ALL COPY :
Copy all MEMO data from the master unit of DN-S5000 (or DN-D9000, DN-2600F) to the slave unit
of DN-S5000 (or DN-D9000) when both unit are connected by the normal straight Cable. (See
diagram for the cable.)
NOTE: Be sure CD player have no discs inside.
A straight cable used:
X'EFFECT OUT
DN-S5000
• Using the straight cable, connect the X-EFFECT terminals between two DN-S5000 units or
between one DN-2600F and one DN-S5000 unit or between one DN-D9000 and one DN-S5000
unit.
• If a DN-2600F is the master unit, take the procedures below in the Preset mode of the DN-2600F
beforehand. (For details, refer to the DN-2600F's operating instructions.)
✽ Set the " Copy Master" for the Preset item (14).
Then, step to the q below on the slave unit of DN-S5000.
• Copying can be performed using the DN-S5000 and DN-D9000 in the same way as when using
two units of the DN-S5000.
DN-S5000-1
DIG TAL OU
IN
MA N
L
L
R
R
POWER
OUT
L NE OUT
MO I OR
ON
OFF
X-EFFECT OUT jack
3.5 mm stereo mini cord
• Perform the copying operation as below on the slave unit of DN-S5000.
q To start copying, push the PARAMETERS knob and select " YES" . Now " Copy OK?"
messages flashes on the character display.
w Push the PARAMETERS knob again to confirm. Now " Start OK?" is displayed.
NOTE: If a DN-2600F is the master unit, take the procedures below in the Preset mode of
the DN-2600F here.
In the Preset item (15), first start copying on the DN-2600F. Then, step to e below
on the slave unit of DN-S5000.
e Push the PARAMETERS knob once again, and the unit starts copying when the MEMO data
are received from the master unit. Now " Copying" is displayed.
• If the master unit and the slave unit are not connected properly or the DN-2600F is not
prepared to start sending data, " Not Connect" is displayed on the character display.
r When copying is completed correctly, " Complete!" is displayed.
• " Copy Error" is displayed on the character display if copying was not completed correctly.
In this case, try the above procedure again.
• The copied MEMO data are added to the highest number area of the slave DN-S5000 unit.
(17) The DN-S5000's software version is displayed. (SYSTEM / DSP / CD DRIVE)
(18) PRESET CLEAR : Set all the preset data back to the factory defaults.
q To clear the PRESET data, push the PARAMETERS.
" Initial OK?" flashes on the character display.
w Push the PARAMETERS knob again and select " OK" to start clear the preset data.
" Preset Int" is displayed on the character display while data clearing.
e Once clearing is completed, " Complete!" is displayed.
ENGLISH
DN-S5000 (X'EFFECT IN)
DN-D9000 (X'EFFECT)
DN-2600F (X'EFFECT)
DN-S5000-2
DIG TAL OU
IN
MA N
L
L
R
R
POWER
OUT
L NE OUT
MON OR
ON
OFF
X-EFFECT IN jack