Broan LOSONE SELECT L2000L Manual Del Usuario
Broan LOSONE SELECT L2000L Manual Del Usuario

Broan LOSONE SELECT L2000L Manual Del Usuario

Ventiladores en línea, para gabinetes
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

LOSONE SELECT
CABINET VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from be-
ing switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and
requirements.
COOKING AREA
Do not install above or
inside this area.
o
45
NOT FOR USE IN
A COOKING AREA.
®
o
45
Cooking
Equipment
Floor
IN-LINE
PLAN INSTALLATION
MOUNTING (Right-angle Discharge)
THREADED ROD
ACCESS
PANEL
DUCT
FLANGES
Factory shipped ready to be installed as a ceiling
MOUNTING (In-line Configuration)
3/8" MIN.
THREADED ROD
(By Others)
INTAKE
FLANGES
Installer: Leave this manual with
Homeowner: Use and Care
MODELS L2000L • L3500EXL
3/8" MIN.
(By Others)
INTAKE
ventilator with right-angle discharge.
ADJUSTABLE
DUCT
Converted for in-line applications.
the homeowner.
information on page 3.
Page 1
MOUNTING
CHANNELS
EXHAUST
CEILING
GRILLE KIT
BRACKET
INTAKE
EXHAUST
ACCESS
PANEL
Tabla de contenido
loading

Resumen de contenidos para Broan LOSONE SELECT L2000L

  • Página 1 MODELS L2000L • L3500EXL Page 1 LOSONE SELECT IN-LINE ® CABINET VENTILATORS READ AND SAVE THESE INSTRUCTIONS PLAN INSTALLATION WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO MOUNTING (Right-angle Discharge) PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone MOUNTING number listed in the warranty.
  • Página 2: Mounting Options

    MODELS L2000L • L3500EXL Page 2 PLAN INSTALLATION (cont.) MOUNTING OPTIONS CONVERTING FROM RIGHT-ANGLE TO IN-LINE DIM. L2000L L3500EXL ACCESS 12-5/8” 12-5/8” PANEL 39-5/8” 47-3/8” 3/8” MIN. THREADED RODS (By Others) EXHAUST DUCT FLANGE EXHAUST DUCT FLANGE INTAKE DUCT FLANGES Remove and reverse duct flanges and access panel positions on housing.
  • Página 3: Electrical Connections

    MODELS L2000L • L3500EXL Page 3 MOUNTING OPTIONS ACCESSORY INSTALLATIONS If ventilator will discharge directly outside, install adamper kit to EXHAUST prevent backdrafts. A grille kit is available for applications where ventilator is installed with direct or remote room air intake. SLEEPER ACCESS PANEL...
  • Página 4: Service Parts

    This warranty supersedes all prior warranties. tains 4 ea. of Key To qualify for warranty service, you must (a) notify Broan at the address stated below or Nos. 2 & 5) telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Página 5: Ventiladores Losone Select En Línea, Para Gabinetes

    MODELOS MODELS L2000L • L3500EXL Page 5 VENTILADORES LOSONE SELECT ® EN LÍNEA, PARA GABINETES LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA INSTALACIÓN PARA REDUCIR EL RIESGO DE INCENDIO, GOLPE ELÉCTRICO, O LESIÓN MONTAJE (descarga en ángulo recto) A PERSONAS, OBSERVE LO SIGUIENTE: 1.
  • Página 6: Instalación (Continúa)

    MODELOS MODELS L2000L • L3500EXL Page 6 INSTALACIÓN (continúa) OPCIONES DE MONTAJE CONVERSIÓN DE ÁNGULO RECTO A EN LÍNEA DIM. L2000L L3500EXL PANEL DE 43 cm. 43 cm. ACCESO D 100,6 cm. 120,3 cm. VARILLAS ROSCADAS DE 9,5 mm. MÍNIMO (no se suministran) BRIDA DEL CONDUCTO DE...
  • Página 7: Instalaciones Accesorias

    MODELOS MODELS L2000L • L3500EXL Page 7 OPCIONES DE MONTAJE INSTALACIONES ACCESORIAS Si la descarga del ventilador es directamente hacia afuera, instale DESCARGA un juego de regulador de tiro para evitar contracorrientes. Hay dis- ponible un juego de parrilla para aquellas aplicaciones en las que el ventilador se instala con una entrada de aire ambiental directa o remota.
  • Página 8: Piezas Para Servicio

    UN PROPOSITO PARTICULAR. (incluye piezas de Durante este período de un año, Broan reparará o cambiará, a su opción y sin cobro, cualquier claves Nº. 30, 31 y producto o pieza que se encuentre defectuosa bajo uso y servicio normal.
  • Página 9 MODÈLES MODELS L2000L • L3500EXL Page 9 VENTILATEURS DE PLACARDS EN LIGNE LOSONE SELECT ® LIRE ET CONSERVER CES INSTRUCTIONS AVERTISSEMENT SCHÉMA DE L’INSTALLATION POUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLES- CONFIGURATION (décharge à angle droit) SURES PERSONNELLES, OBSERVEZ CE QUI SUIT: 1.
  • Página 10: Configurations Possibles

    MODÈLES MODELS L2000L • L3500EXL Page 10 SCHÉMA DE L’INSTALLATION CONFIGURATIONS (suite) POSSIBLES CONVERSION ANGLE DROIT - EN LIGNE DIM. L2000L L3500EXL PANNEAU D’ A C- 43 cm 43 cm CÈS 100,6 cm 120,3 cm TIGE FILETÉE DE 9,5 mm MIN. (autres fabricants) BRIDE DU CONDUIT D’ÉCHAPPE-...
  • Página 11: Branchements Électriques

    MODÈLES MODELS L2000L • L3500EXL Page 11 CONFIGURATIONS POSSIBLES INSTALLATION DES ACCESSOIRES Si la décharge du ventilateur se fait directement à l’extérieur, installer le kit de registre pour empêcher les refoulements. Un kit de grille est ÉCHAPPEMENT disponible pour les applications où le ventilateur est installé avec admission d’air directe ou à...
  • Página 12: Pièces De Rechange

    Cette garantie annule toutes les garanties précédentes. 98006479 98006480 Volet de registre Pour le service sous garantie, vous devez (a) aviser Broan á l’adresse ci-dessous, (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la nature de tout 98006481 98006472 Tige de registre défaut dans le produit ou la pièce.

Este manual también es adecuado para:

Losone select l3500exlLosone select l2000l

Tabla de contenido