TROUBLESHOOTING
PROBLEM
The burner will not
light with a match.
obstructed gas
POSSIBLE CAUSE
1. Match not reaching burners
(when holding match with
hand).
2. Empty tank.
3. Poor connection between
valve regulator and LP
cylinder coupling.
4. Burner inlet blocked.
1. Tank valve not on or fully
opened.
2. Empty tank.
3. Poor connection between
valve regulator and LP
cylinder coupling.
4. Burner inlet blocked.
CORRECTIVE ACTION
1. Use match holder found in
cabinet door.
necessary.
3. Turn off grill knobs, close the LP
cylinder valve at top of cylinder
and check the connection
between the regulator valve
and cylinder coupling.
Disconnect and reconnect, if
necessary.
4. Clean the burner inlet (venturi)
and burner as described by the
Care and Maintenance section
in the manual.
1. Fully open tank valve by turning
counterclockwise.
2. Check fuel level and replace
fuel if necessary.
3. Turn off grill knobs, close the LP
cylinder valve at top of cylinder
and check the connection
between the regulator valve
and cylinder coupling.
Disconnect and reconnect, if
necessary.
4. Clean the burner inlet (venturi)
and burner as described by the
Care and Maintenance section
in the manual.
27