Tone Generator; Bottom View - Southwire T100PK Instrucciones De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Tester Description

Tone Generator

1. Tone LED
2. TEST button
3. Tone/Continuity
selector switch
4. Polarity/Continuity LED
Amplifier Probe
Top View
1. Earphone jack
2. Signal indicator light
3. On/Off button
4. LED flashlight
5. Non-metallic tip
1.

Bottom View

1. Battery cover
2. Volume control
1.
3. Screw for
non-metallic tip
4. Non-metallic tip
1.
2.
Top View
2.
3.
2.
Bottom
3.
View
3
Tracing Cables
This function allows the user to locate the path of the cable
behind walls and hidden locations.
4.
WARNING:
in excess of 60 volts. Do not touch the metal test lead tips when making a
connection. Never allow the amplifier probe to contact voltage sources,
3.
such as wiring to an electrical outlet.
NOTE:
Use caution when tracing installed cables. The tone generator may
cause interference with signals on adjacent conductors.
Black
5.
4.
1. Set the TONE/CONT switch to the TONE position.
2. Connect the red test lead to the one of the wires of the cable
being traced. If the cable is shielded, connect the red test lead
to the shield. Note that connecting both test leads to the same
4.
cable will reduce the radiated signal.
3. Turn the tone generator on by pressing the Tone Button once
for a continuous tone and twice for a pulse tone.
4. Move the amplifier probe towards the suspected path of the
cable. The tone will be progressively louder as the probe gets
closer to the cable the tone is being sent through.
Never connect to AC voltage. Do not connect to DC voltage
Red
4
Amplifier Probe
(searching for cable)