Copyright; Safety Rules; Basic Safety Precautions; Safety Symbols - zarges Z600 Instrucciones De Montaje Y Uso

Ocultar thumbs Ver también para Z600:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1.6

Copyright

• The copyright for these Assembly and Use Instruc-
tions remains with the manufacturer.
2

SAFETY RULES

2.1

Basic safety precautions

• The following specifications are applicable to the in-
stallation and use of the systems:
Standard / specifi-
cation
DIN EN ISO 14122
Fixed access to machines and industri-
al systems like working platforms,
module systems, all systems
BGI 561
Industrial access steps, bridging plat-
forms, platform steps, step platforms,
raised steps, working platforms, mod-
ule systems.
BGI 594
All systems if electrical resources are
used
BGV D36
Industrial access steps, bridging plat-
forms, platform steps, step platforms,
raised steps, working platforms, mod-
ule systems.
2.2

Safety symbols

The following names and signs for dangers are used in
these Assembly and Use Instructions:
This symbol warns about a danger spot.
This symbol provides tips and instructions
about the optimal use of the systems
This symbol gives instructions for the
proper disposal and storage of ensuing
waste.
2.3

Proper use according to manufacturer instructions

The systems listed in the present Assembly and Use in-
structions should be used only as climbing aids for work-
ing positions that are not within reach at the body height
level. Please ensure that the maximum weight carrying
capacity is not exceeded.
Approved use also implies:
• Observance of all guidelines mentioned in these As-
sembly and Use Instructions, and
• performing the regular checks.
o
N
291311
Scope
- 19 -
2.4

Unapproved use

An unapproved use – i.e., any departure from the infor-
mation on the systems described in section
Assembly and Use Instructions - is an unapproved use in
the sense of product safety legislation. This also applies
to the non-observance of the standards and directives
mentioned in these Assembly and Use Instructions.
2.5

Special safety provisions

2.5.1
Behaviour while working with electrical equipment on the sys-
tems
If electrical equipment is operated from a mains connec-
tion (drill etc.), the following instructions must be ob-
served.
When working with electrical equipment on the platform,
the BGI 594 specifications must be applied.
Electrical equipment may only be operat-
ed with protective low voltage (48 V) with
protective isolation (isolation transform-
er) or when connected via a fault-current
circuit breaker with a fault current < 30
mA. A construction power distributor
should be used to supply the power.
The extension cable for the electrical equipment must be
selected so that it has an adequate cable cross-section
for the equipment. Hose cables of the type H07RN-F
should be used as extension cables.
2.5.2
Conduct when working on electrical installations from the sys-
tems
The systems may not be used to work on or close to un-
protected live electrical installations unless
• the electrical installations is switched off,
• the electrical installations is locked against unin-
tended reactivation,
• the electrical installations is not running voltage,
• the electrical installations is short-circuited with the
help of earthing rails and
• the electrical installations is insulated from adjacent
live parts.
3

PACKAGING AND TRANSPORTATION

The systems must be bound securely to prevent them
from sliding during transportation via vehicles.
2.3
of these
GB
Tabla de contenido
loading

Este manual también es adecuado para:

291311

Tabla de contenido