Parameter / Register - marklin 55224 Manual Del Usario

Modell der elektrolokomotive br 194
Tabla de contenido
CV
Discription
01
Address
02
PoM Minimum Speed
03
PoM Acceleration delay
04
PoM Braking delay
05
PoM Maximum speed
08
Factory Reset / Manufacturer Recognition
13
PoM Functions F1 - F8 in analog operation
14
PoM Functions F9 - F15 and lights in analog operation
17
Extended address (upper part CV29 Bit 5 = 1)
18
Extended address (lower part CV29 Bit 5 = 1)
19
Multiple Unit Address
21
PoM Functions F1 - F8 on Multiple Unit
22
PoM Functions F9 - F15 and lights on Multiple Unit
Bit 0: Reversing direction
Bit 1: Number of speed levels 14 or 28/128
29
Bit 2: DCC operation with braking area
Bit 5: Address length 7 Bit / 14 Bit
Multiple station announcements
Bit 0 – 3 = Number of stations
60
PoM
Bit 4 = Last station reverses the sequence.
Bit 5 = Locomotive direction determines the sequence.
Bit 6 = Basic setting for sequence.
63
PoM Volume
138 PoM Volume for sound "squealing brakes"
139 PoM Volume for sound "operating sounds"
140 PoM Volume for sound 1 (whistle)
Betrieb • Operation • Fonctionnement
6021 Value
DCC Value
01 – 80 (1 + 2)
CV 29/Bit 5 =0
01 – 63
01 – 63
01 – 63
08
192 – 255 (192)
01 - 63 (63)
16
1 – 127 (3)
0 – 255 (25)
0 – 255 (15)
0 – 255 (15)
0 – 255 (245)
08 (131)
0 – 255 (0)
0 – 255 (1)
0 – 255 (128)
0 – 255 (0)
0 – 255 (0)
0 – 255 (0)
0 / 1 (0)*
0 / 2 (2)*
0 / 4 (4)*
0 / 32 (0)*
0 – 127 (0)
0 – 255 (255)
0 – 255 (255)
0 – 255 (255)
0 – 255 (255)
Exploitatie • Operación • Operazione
Tabla de contenido
loading

Tabla de contenido