6. Wall Control Installation
6.6
Connect the Wall Control BLACK wire to the Fan/Motor
Lead (BLACK or RED) wire using a new wire connector
NOTE: Use only the wire connectors supplied with the
(supplied) (Figure 23).
new wall control to secure electrical connections.
6.7
Connect the Wall Control BLACK wire to the 120 VAC
source hot BLACK wire using a new wire connector
(supplied) (Figure 24).
6.8
Securely connect the GREEN ground wire from the Wall
Control to the supply ground wire (bare or green
(Figure 25).
WARNING
!
Check to see that all wire connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for ground.
(Continued)
FAN/MOTOR BLACK
OR RED WIRE
WIRE
CONNECTOR
WALL CONTROL
Figure 23
WIRE CONNECTOR
WALL CONTROL
BLACK WIRE
120 VAC HOT
BLACK WIRE
WALL
CONTROL
Figure 24
WALL CONTROL
GREEN GROUND
WIRE
Figure 25
Please contact 1-800-654-3545 for further assistance
15
TO FAN MOTOR
LOAD
WALL
CONTROL
BLACK WIRE
TO 120VAC
SOURCE
HOT
TO FAN
MOTOR LOAD
TO 120VAC
SOURCE HOT
SUPPLY GREEN
GROUND WIRE
WIRE
CONNECTOR
emersonfans.com