time in the tub.
7) If you want to use salts or other substances with relaxing, toning,
slimming, etc., effects, please ensure they will not cause foam formation
and that they are well dissolved in the water prior to turning on the
pump.
Electrical connection:
The manufacturer guarantees compliance to the current safety and health
regulations at the time of sale, through the CE mark and the declaration
of compliance. All of the parts and components are factory inspected as
described in the reference standards and according to the company's
quality management system. For the safety characteristics to remain
unchanged following installation and during the entire lifetime of the
tub, please follow the simple instructions provided.
1) Make certain that the electric system to which the tub will be connected
has been installed according to current regulations and standards,
with special care for the ground connection.
2) The current standards prohibit electric installations (outlets, switches,
etc.) in an area around the tub for a distance of at least 60 cm and a
height of 225 cm.
3) Check that the electric cable that powers the tub is sized correctly
according to the power indicated (please see the technical characteristics
on page 27/37/46).
4) The tub's connection point to the electric system must be installed so
as to be protected from splashing water (IP protection rating IP55 or
greater).
5) Upstream from the tub in the electric system there must be a 30 mA
differential circuit breaker with an omnipolar switch with a minimum
opening of 3 mm between the contacts.
6) There is a ground terminal on the tub which must be connected to
the ground circuit for the supplemental equipotential connection
between the metal masses in the tub
26/36/44/45).
(please see the figure on page
-7-