Storage And Transportation; Technical Specification - 3M itarus Versaflo M Serie Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Forehead comfort pad. - Detach the comfort pad from the headband. Wrap the
replacement comfort pad around the headband and re-attach (Fig 21).
Head, neck and shoulder cover (M-100/M-200/M-300 Series only). - Remove the black
visor gasket from the groove (Fig 20). Insert headtop into cover and pull the air inlet fully
through the opening in the back of the cover. Insert the gasket on the cover firmly and
fully into the groove on the top of the visor frame.
Flame resistant headtop cover. - Remove the black visor gasket from the groove (Fig
20). Insert the gasket on the cover firmly and fully into the groove on the top of the visor
frame. Pull loop on headtop cover over the air inlet on the headtop. The air inlet fits
through the hole in the back of the cover. Note: If fitting the cover in combination with the
ear muff assembly, please see the ear muff assembly instructions below.
Chin strap. - Attach the chin strap to the attachment points on the head suspension (Fig 22).
Headtop mounted ear muff assembly (M-100/M-200/M-300 Series only). - Locate the
attachment points (Fig 23 and 24 ). As worn, the right side mount is marked 'X' and the
left side mount is marked 'O' (Fig 25). The earmuff should be attached as shown in Fig
26. Use a screwdriver to push in the attachment points before screwing the ear muff
assembly as tightly as possible to the shell.
Note: If using the ear muff assembly in combination with the flame resistant headtop
cover, the attached ear muffs must first be pulled through the slits in the headtop cover
before pulling the loop on the cover over the air inlet.

STORAGE AND TRANSPORTATION

These products should be stored in the packaging provided in dry, clean conditions away
from sources of high temperature and petrol and solvent vapours.
^ Do not store in direct sunlight.
Do not store outside the temperature range -30°C to +50°C or with humidity above 90%.
If the product will be stored for an extended period of time before use, the suggested
storage temperature is 4°C to 35°C.
When stored as stated, the maximum life (shelf life plus in-use life) is 5 years from date of
manufacture. The original packaging is suitable for transporting the product throughout
the European Union.

TECHNICAL SPECIFICATION

(Unless otherwise stated in the Reference Leaflet)
Respiratory Protection
M-100 Series
Nominal Protection Factor = 10 Assigned Protection Factor = 10
EN12941 TH1 when connected to 3M™ Dustmaster Powered Air Turbo.
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Versaflo™ TR-802E, 3M™ Versaflo™ TR-602E,
3M™ Versaflo™ TR-302E/TR-302E+, 3M™ Jupiter™ and 3M™ Adflo™ Powered Air
Turbos.
EN14594 2B when connected to 3M™ Versaflo™ V-100E, V-200E, V-500E and 3M™
Flowstream™ Regulators.
EN1835 LDH2 when connected to 3M™ Vortemp™ and 3M™ Vortex Regulators.
M-200 Series
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Jupiter™ Powered Air Turbo.
Nominal Protection Factor = 500 Assigned Protection Factor = 40
EN12941 TH3 when connected to 3M™ Versaflo™ TR-802E, 3M™ Versaflo™ TR-602E
and 3M™ Versaflo™ TR-302E/TR-302E+ Powered Air Turbos.
Nominal Protection Factor = 200 Assigned Protection Factor = 40
EN14594 3B when connected to 3M™ Versaflo™ V-100E, V-200E and V-500E
Regulators.
M-300 Series
Nominal Protection Factor = 10 Assigned Protection Factor = 10
EN12941 TH1 when connected to 3M™ Dustmaster Powered Air Turbo.
Nominal Protection Factor = 500 Assigned Protection Factor = 40
EN12941 TH3 when connected to 3M™ Versaflo™ TR-802E, 3M™ Versaflo™ TR-602E
and 3M™ Versaflo™ TR-302E/TR-302E+ Powered Air Turbos.
Nominal Protection Factor = 200 Assigned Protection Factor = 40
EN14594 3B when connected to 3M™ Versaflo™ V-100E, V-200E and V-500E
Regulators.
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Jupiter™ and 3M™ Adflo™ Powered Air
Turbos.
EN14594 2B when connected to 3M™ Flowstream™ Regulator.
EN1835 LDH2 when connected to 3M™ Vortemp™ and 3M™ Vortex Regulators.
M-400 Series
Nominal Protection Factor = 10 Assigned Protection Factor = 10
EN12941 TH1 when connected to 3M™ Dustmaster Powered Air Turbo.
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Adflo Powered Air Turbo
Nominal Protection Factor = 500 Assigned Protection Factor = 40
EN12941 TH3 when connected to 3M™ Versaflo™ TR-802E, 3M™ Versaflo™ TR-602E,
3M™ Versaflo™ TR-302E/TR-302E+ and 3M™ Jupiter™ Powered Air Turbos.
Nominal Protection Factor = 200 Assigned Protection Factor = 40
EN14594 3B when connected to 3M™ Versaflo™ V-100E, V-200E and V-500E
Regulators and 3M™ Flowstream™ Regulator.
EN1835 LDH3 when connected to 3M™ Vortemp™ and 3M™ Vortex Regulators.
Note: When regulators and compressed air supply tubes that are exclusively marked
EN1835 are used with M-Series headtops, the system will only meet the requirements of
EN1835.
Note: The M-Series headtops meet the higher strength (B) requirements of EN14594.
They are approved for use with a range of compressed air supply tubes that meet both
the lower and higher strength (A and B) requirements. Please see Equipment Marking
section of relevant Regulator User Instructions for information.
Nominal Protection Factor (NPF) - a number derived from the maximum percentage of
total inward leakage permitted in relevant European Standards for a given class of
respiratory protective devices.
Eye Protection
Visor surround - EN166:3:9:BT (Liquid splash 3, molten metal 9 and medium energy
impact at extremes of temperature BT).
M-925 Visor – EN166:1:BT:3:9 (Optical class 1, medium energy impact at extremes of
temperature BT, liquid splash 3 and molten metal 9)
M-927 Visor – EN166:1:BT:3 (Optical class 1, medium energy impact at extremes of
temperature BT and liquid splash 3).
Head protection
The M-206 and M-207 headtops with M-200 helmet shell meet the requirements of
EN812 (see below).
440 V a.c. - Electrical insulation.
The M-306 and M-307 headtops with M-300 helmet shell meet the requirements of
EN397 (see below).
The M-406 and M-407 headtops with M-400 helmet shell meet the requirements of
EN397 (see below).
LD - Lateral deformation.
440 V a.c. - Electrical insulation.
Flow Characteristics
Manufacturers Minimum Design Flow (MMDF).
170 l/min (3M™ Versaflo™ TR-802E, 3M™ Versaflo™ TR-602E and 3M™ Versaflo™
TR-302E/TR-302E+ Powered Air Turbo and 3M™ Versaflo™ V-100E, V-200E and
V-500E Regulators)
160 l/min (3M™ Adflo™ Powered Air Turbo)
150 l/min (3M™ Jupiter™ and Dustmaster™ Powered Air Turbo and 3M™
Flowstream™, 3M™ Vortemp™ and 3M™ Vortex Regulators).
Note: When using the M-400 Series headtops in combination with the 3M™ Vortemp™
and 3M™ Vortex Regulators, the recommended pressure range is 4 - 6 bar).
Maximum Flow - See appropriate User Instructions.
Head Size
One size, adjustable to fit 51cm to 64cm (UK sizes 6 – 8).
Breathing tube lengths
BT-20S – 735mm (29 inches)
BT-20L – 965mm (38 inches)
BT-30 – 525mm to 850mm (21 inches to 34 inches)
BT-40 – 840mm (33 inches)
834008 - 950mm (37 inches)
834016 - 525mm to 850mm (21 inches to 24 inches)
834017 - 775mm (31 inches)
Operating Temperature
-10ºC to +55ºC
Weight:
M-106 605 g, M-107 605 g, M-206 650g, M-207 650g, M-306 873 g, M-307 873 g, M-406
1196 g and M-407 1147 g.
6
Tabla de contenido
loading

Tabla de contenido