GZX
USER INSTRUCTIONS
Please read these instructions in conjunction with the 3M™
Facepiece User Instructions where you will find information on:
•Approved combinations of facepieces and filters
• Accessories
• Spare parts
SYSTEM DESCRIPTION
These products meet the requirements of EN 14387:2004 +
A1:2008 Gas Filter(s) and Combined Filter(s) and should be used in
combination with an approved 3M™ Secure Click™ Masks to form
a filtering apparatus for respiratory protection.
The Facepiece/Filter combination is designed to remove potentially
harmful gases, vapours and particulates from the surrounding
atmosphere. Filter performance data is detailed in the Technical
Specification.
Particular attention should be given to warning statements
where indicated.
^ WARNINGS AND LIMITATIONS
• Proper selection, training, use and appropriate maintenance
are essential in order for the product to help protect the wearer
from certain airborne contaminants. Failure to follow all
instructions on the use of these respiratory protection
products and/or failure to properly wear the complete product
during all periods of exposure may adversely affect the
wearer's health, lead to severe or life threatening illness or
permanent disability.
•Always be sure that the Facepiece/Filter combination is:
- Suitable for the application;
- Fitted correctly;
- Worn during all periods of exposure;
- Replaced when necessary.
For suitability and proper use follow local regulations and refer to all
information supplied. For more information contact a safety
professional or 3M on 0870 60 800 60 (UK) or 1800 320 500
(Ireland).
Use this respirator system strictly in accordance with all instructions:
• contained in this booklet
• accompanying other components of the system
• Do not submerge the filters in liquid.
• Do not use in atmospheres containing less than 19.5% oxygen.
(3M definition. Individual countries may apply their own limits on
oxygen deficiency. Seek advice if in doubt).
• Do not use these products in oxygen or oxygen-enriched
atmospheres.
• Do not use for respiratory protection against atmospheric
contaminants/concentrations which have poor warning properties or
are unknown or immediately dangerous to life and health (IDLH) or
against contaminants/concentrations which generate high heats of
reaction with chemical filters.
• CAUTION: Work with open flames or liquid metal droplets may
cause serious risk due to the ignition of filters.
• In case of intended use in explosive atmospheres, contact 3M.
• Do not use in concentrations above those specified in the
Technical Specification.
• Leave the contaminated area immediately if:
a)Any part of the system becomes damaged.
b)Airflow to the facepiece decreases or stops.
c) Breathing becomes difficult or increased breathing resistance
occurs.
d) Dizziness or other distress occurs.
e) You smell or taste contaminants or irritation occurs.
• Never alter, modify or repair this device.
• These products do not contain components made from natural
rubber latex.
NOTE Save all user instructions for continuing reference.
PREPARATION FOR USE
Remove the filter from its outer packaging. CAUTION: Care should
be exercised when using previously unpacked filters as they
may have reduced service life or may have been used.
Check that the filter is appropriate for the purpose – check colour
code, letter code and class. Before initial use, always check that the
product is within the stated shelf life (use by date). Inspect each
cartridge for any visible damage to the cartridge. Ensure the plastic
cartridge connector is not damaged. Do not use damaged
cartridges.
ASSEMBLY INSTRUCTIONS
1.Align the port end of the cartridge or filter with the port on the
facepiece (Fig. 1).
2. Push the filter into the connector until you hear a click and the blue
filter release button raises back to its initial position prior to attaching
the cartridge/filter (Fig. 2). If the cartridge does not "click" into place
when inserted it may be due to the angle of insertion. Lift up slightly
on the cartridge until the cartridge clicks into place (Fig. 3).
3. Repeat with second filter.
4. To remove the cartridge depress the blue cartridge/filter release
button and simultaneously pull outward on the cartridge (Fig. 4).
If using D805X/D807X with a replaceable D7900 prefilter, please
see user information supplied with D7900 filters for assembly
information.
Replace cartridge in accordance with an established change
schedule or earlier if smell, taste or irritation from contaminants is
detected. The service life of filters will depend upon the activity of the
wearer (breathing rate); the specific type, volatility and concentration
of the contaminants; and environmental conditions such as humidity
and temperature.
CLEANING INSTRUCTIONS
Clean with the 3M™ 105 Face Seal Cleaner.
STORAGE AND TRANSPORTATION
These products should be stored in the packaging provided in dry,
clean conditions away from direct sunlight, sources of high
temperature, petrol and solvent vapours. The original packaging is
suitable for transporting the product throughout the European Union.
Storage conditions on the packaging refer to annual average
temperature and relative humidity values.
indicates acceptable storage conditions. indicates unacceptable
storage conditions. See Fig. 5.
Storage under conditions other than those specified by the
manufacturer may affect the shelf life.
When stored as stated, the expected shelf life of the product is 5
years from date of manufacture.
Do not use the product after the expiration date.
3