ENGLISH
14
C
Damaged or worn shaving heads (cutters and
guards) must only be replaced with original HQ6
Philishave Quadra shaving heads.
◗ Put the retaining frame back into the shaving
unit, press the wheel and turn it clockwise.
2
The shaver does not work when the on/off
button is pressed.
Cause: the batteries are empty.
B
◗ Recharge the batteries. See chapter 'Charging'.
3
The shaving unit has become detached
from the shaver.
◗ If the shaving unit becomes detached from the
shaver, check whether the hinge spring is still
properly attached, i.e. has not come loose and
does not show any cracks or damage. If the
hinge spring is still properly attached, the
shaving unit can be easily put back onto the
shaver. However, if the hinge spring has come
loose, is cracked or damaged, contact your
Philips dealer or the nearest Philips service
centre to have the hinge replaced, as a broken
hinge could damage the body of your shaver.