Pumped Liquids - Saci V-NOX Serie Manual De Instalación Y Mantenimiento

Bombas verticales multicelulares
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PUMP INSTALLATION AND MAINTENANCE MANUAL
(Instructions based on Spanish)
1 - GENERAL
Before installing, carefully read these instructions, which contain the basics for you to get to know the
pump and get the best out of its possible use. If these indications are followed, the components of the
pump will have a long life and hazards will be avoided. This manual must always be kept alongside the
pump. Both the installation and the operation shall meet the safety requirements of the country where the product
is installed. All work will be done with the utmost care and exclusively by qualified personnel with the requirements
of current regulations. Any infringement of the safety regulations, in addition to putting people at risk and causing
damage to the apparatuses, will cause the loss of all right to guarantee. Units will always be installed vertically.
2 - APPLICATIONS AND USE
Multi-cellular vertical centrifugal pumps connected by oval flanges. Their projection and manufacturing features are
at the forefront of technology and stand out thanks to the particular services that guarantee maximum output with
total reliability and solidity. They may be used in a wide variety of situations, such as pressure units for buildings,
watering, fire prevention equipment, etc.
The machine has been designed to pump water that is free from explosive substances, with a density equivalent to
1000 Kg/m
and a kinematic viscosity of 1 mm
3
It has no uses other than the one previously described.

3 - PUMPED LIQUIDS

The pump is conceived and manufactured to pump clean, pure, non-aggressive liquids.
4 - TECHNICAL DATA AND LIMITS OF USE
Pump
- Maximum pumped liquid temperature: +40°C
- Turning speed: 2900 1/min
- Flow: from 1 m
/h to 45 m
3
- Raising speed: up to 160 m
- Maximum ambient temperature: +45°C
- Storage temperature: -10°C +40°C
- Max. relative humidity of air 95%
- Weight: see catalogue for technical data.
Motor
- Supply voltage: 3 x 230-400 V 50/60 Hz up to 4 KW including 3 x 400/690 V 50/60 Hz over 5.5 KW
- Motor protection: IP55
- Isolation class: F
- Absorbed power: see electrical data plate
- Motor construction: According to CEI 2 Standards – 3 issue 1110
If a protection fuse is activated in a three-phase motor, it is best also to replace the other
two fuses along with the one that has blown.
/s, as well as chemically non-aggressive liquids.
2
/h depending on the model
3
12
ENGLISH
Tabla de contenido
loading

Este manual también es adecuado para:

Vat serieV-nox 300V-nox 400Vat 127Vat 163Vat 205

Tabla de contenido