Technical Data - Kärcher IVR-B 20/6 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Switch off the device before performing
any work on the device.
Remove the mains plug.
Have all checks and work on electrical
parts performed by an expert.
The motor (suction turbine) does
not start up.
No electrical voltage present.
1. Check the socket and the power
supply fuse.
2. Check the mains cable and the
mains plug of the device.
The motor circuit breaker has tripped.
1. Allow the motor to cool down.
2. Check the suction hose, the contain-
er and the exhaust outlet for a block-
age.
3. Switch the device on.
4. If the motor circuit breaker trips
again, cease operation and contact
Customer Service.
The suction power decreases.
Nozzle, suction hose or suction pipe
clogged.
1. Check the nozzle, the suction hose
and the suction pipe and clean if
necessary.
The filter is dirty.
1. Clean the filter.

Technical data

Electrical connection
Mains voltage
Phase
Power frequency
Nominal power
Protection class
Protection class
Power protection (slow-
blowing)
Device performance data
Container capacity
8
V
460
~
3
Hz
60
W
630
IP 55
I
A
16
gal/m
5.3
(l)
(20)
English
Air quantity
Vacuum
Suction hose connec-
tion
Dimensions and weights
Typical operating
weight
Length x width x height mm
Ambient conditions
Ambient temperature
(max.)
Determined values in acc. with EN
60335-2-69
Hand-arm vibration val-
ue
K uncertainty
Sound level L
pA
K uncertainty
pA
Subject to technical modifications.
CFM
103
(l/s)
(48.6)
kPa
7 (70)
(mbar)
in
2.1
(mm)
(50)
kg
25
570 x
625 x
498
°C
+5 -
+40
2
m/s
< 2.5
m/s²
0.2
dB(A) 65
dB(A) 2
Tabla de contenido
loading

Tabla de contenido