S004
HOME key
3. Setting the Fuel Gas Type (If Band P (LPG) is Used)
* When using Band P (LPG) for fuel gas, the gas type has to be confi gured.
* The outdoor unit power breaker remains OFF.
(1) Move the lever of the N/P switch that is attached to the mixer part of the engine to the position shown in the diagram. Turn
it 180 degrees in the anticlockwise direction (there is a stopper provided). Do not apply unnecessary force to turn it any
further.
(2) Please mount the attached short-circuit
connector to the N/P switch CN013 (Fig. 1) of
the outdoor control board.
* Switch on the power breaker of the outdoor
unit.
(3) Apply the < Gas type set and adjusted > label in the PL NAME designated location in the electrical box.
4. Checking the Date and Time
Checking
(1) Select the
Example:
(2) With the date displayed, press the SET key to switch to the time display.
Example:
(3) With the time displayed, press the SET key to switch back to the date display.
* If the current date and time display are not correct, reset (correct) them.
Setting (correcting)
(1) With the date or time displayed, press and hold the SET key for 1 second to enter setting mode.
Example:
(2) Each time the SET key is pressed, the setting contents are confi rmed and the fi rst digit display changes. The settings are
as shown in Table 2. After
00̲M2̲TestRun̲All.indb 5
00̲M2̲TestRun̲All.indb 5
S006
S007
DOWN key
SET key
VG (gas closing valve force-closing)
switch
After installing, be sure to
check that there is no gas leak-
age. There is the danger of fi re
if gas leaks.
(date display) menu item to display the current date.
(April 1, 2012)
(11 h 05 m 25 s)
(2012)
is displayed for the fi rst digit, the display returns to
N/P switch
Fig. 1
Lever
When shipping
Fig. 2
.
EN - 5
Termination resistance -
Presence/absence switch
STOP (collective stop)
switch
When the Band P (LPG) is setting