Maintenance - Troubleshooting - Pentair SIATA V132 Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para SIATA V132:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

V 1 3 2
MAINTENANCE
Attention
Any valve maintenance and/or installation operation must be carried out in the
absence of hydraulic pressure. For this reason, disconnect the water delivery
line to the valve.
Troubleshooting
E
Fault
N
Leaks to the drain
G
during service or
when in stand-by
L
I
S
H
Hard water during
service
No brine draw
Cause
Corrective action
Leak from pilot
1 - Turn off the water inlet.
2 - Turn off the water outlet.
3 - Disconnect the connection tube between the pilot and the drain connection.
4 - Remove the 3 screws securing the manifold. Remove both o-rings and replace
them with two soft rubber discs of the same outer diameter, each measuring
2mm in thickness.
5 - Refit manifold by tightening the three screws and taking care not to
force them.
6 - Reopen the water inlet and outlet. Once the procedure is complete, if the outlet
leak has disappeared, the fault was due to the pilot. Replace the pilot.
Leak at inside of pilot
Replace pilot group reference 2250/05.
chambers
Valve leak through
If it is observed that the leak is coming only from the drain, it can easily
the piston system.
be determined which chamber/piston is leaking.
7 - If the water leaking from the outlet is hard, the assembled inlet piston needs
to be replaced, reference 1918/05.
8 - If the water leaking from the outlet is soft, the assembled outlet piston needs
to be replaced, reference 1918-C/05.
Probable leakage
9 - Remove the valve from the tank, replace the seal (O-ring on top of tank) between
between inlet and
the valve adapter and the riser tube.
outlet or on
10 - Remove the inlet piston, check for obvious surface damage. If the piston is
valve/tank seal
Bypass valve not
Ensure that the bypass valve is fully closed.
closed
Low water pressure
11 - Close the inlet to the valve, check that the pressure gauge shows
at the inlet
12 - If the pressure is higher than 2 bar, check whether the mechanical filter which is
Pre-filter above pilot
13 - Remove manifold, remove filter and clean thoroughly.
blocked
Plugged injector
14 - Remove injector, thoroughly clean the holes in the injector and refit the assembly.
Problems in salt/brine
15 - Thoroughly check the connection assembly to the brine tank:
tank
g) - Check that there are no obstructions in the connection system.
h) - Check that there is a flow when the float is in lower position.
i) - Check that there is no formation of a salt bridge in the brine tank.
j) - Check that all components of the brine valve operate efficiently without any
leaks from any fittings.
damaged, replace it.
a pressure of at least 2 bars. If it is lower, the pressure is insufficient.
installed before the valve is blocked. Remove and clean.
24
Tabla de contenido
loading

Tabla de contenido