Self-Diagnosis; Battery Charging - Black Diamond Jetforce Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
english
JETFORCE SYSTEM COMPONENTS
See also: Figure 1, Inside Front Cover
1a: Main Cargo Compartment
1b: Deployment Handle Pocket
1c: Deployment Handle
1d: Power Button
1e: System Status Lights
1f: Charge Status Lights
1g: Lithium-Ion Battery
1h: Charging Plug
1i: Airbag Pocket
1j: Airbag Release Mechanism
1k: Release Clips
1l: Release Flap
1m: Back Panel Flap
1n: Accessory Pouch
SYSTEM FUNCTION
When the airbag is deployed by pulling the Deployment Handle
(1c), the two Release Clips (1k) are released allowing the Release
Flap (1l) to open, then the inflating airbag opens the airbag
zipper. The airbag can then fully inflate (Figure 2).

SELF-DIAGNOSIS

To ensure that your JetForce Avalanche Airbag will function
properly, the JetForce electronic system performs a
comprehensive self-diagnosis on every system startup.
The system checks the battery charge level, motor and fan
operation and all critical electronics such as status lights,
trigger electronics and the battery electronics. The system also
performs frequent diagnosis while armed. System malfunctions
are indicated on the System Status Lights (1e, 1f), located on the
Deployment Handle (1c).
2
1o: JetForce Backpack
Instructions
1p: Charging Power Supply
3a: Leg Strap
3b: Left Waist Belt Pocket
3c: Left Side Buckle
3d: Leg Strap Loop
3e: Right Side Buckle
3f: Sternum Strap
5a: Fan Housing
5b: Air Release Slider
5c: Zipper Pull
5d: Zipper Pull Illustration
5e: Reset Tab

BATTERY CHARGING

Always make sure the system has a full charge before heading
out into avalanche terrain.
Only charge the battery using the provided JetForce Airbag
charger (type: EGSTON E2CFHW3).
1. Locate the Charging Power Supply (1p) and install the
correct international plug.
2. Locate the small zippered charging connector pocket on
the inner surface of the open Back Panel Flap (1m).
3. Unzip and expose the Charging Plug (1h).
4. Plug the Charging Power Supply (1p) cable into the
Charging Plug (1h).
5. Plug the Charging Power Supply (1p) into an electrical
outlet.
6. The Deployment Handle (1c) will illuminate a pulsing
green light within the System Status Lights (1e). The
charge level is shown by the solid blue Charge Status
Lights (1f) with one blue light flashing to indicate
charging state.
WARNING! The airbag will deploy if the Deployment Handle is
pulled anytime the lights are illuminated, even during charging.
7. Charge until the Deployment Handle (1c) shows full
charge with 4 solid blue lights.
1st time charging can be as long as 12 hours.
Typical charging time is less than 6 hours.
8. Charge the Lithium-Ion Battery (1g) at room
temperature. Do not charge at temperatures outside of
range (0°C to 45°C / 32°F to 113°F). At these extremes the
system will indicate an error Status Light and shut off the
charging cycle.
9. A flashing red light or solid red light on the JetForce