Troubleshooting - Cash Acme TANK BOOSTER HEATGUARD 020 Serie Manual Del Usuario

Ocultar thumbs Ver también para TANK BOOSTER HEATGUARD 020 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4. Troubleshooting

FAULT / SYMPTOM
The desired mixed water
temperature cannot be
obtained or valve is diffi-
cult to set.
Mix temperature unstable
or changing over time.
Either full hot or full cold
water flowing from outlet
fixture.
TANK BOOSTER
Installation Instructions
IS279 REV L
2-17-16
CAUSE
Inlet temperatures are not
within specific limits.
Hot and cold supplies are
reversed.
Strainers are blocked.
Strainers are blocked.
Fluctuating supply pres-
sures.
Valve is incorrectly set.
Hot and cold supplies are re-
versed
Hot/Cold water has migrated
to other inlet.
Refer also to point 1.
21
RECTIFICATION
Ensure inlet tempera-
tures are within the spec-
ified limits for the valve.
Refit the valve with Hot/
Cold supplies fitted to the
correct connections.
Clean strainers.
Clean strainers.
Install pressure regu-
lating valves on both hot
and cold supplies.
Adjust mix temperature as
required.
Refit the valve with Hot/Cold
supplies fitted to the
correct connections.
Check non-return valve is not
fouled. Clean if neces-
sary.
Tabla de contenido