Models ICB424 and ICB424FS Installation
Models ICB424 and ICB424FS Installation
The Sub-Zero model ICB424FS wine storage unit is
designed to be attractive in a stand alone setting. It can
also be slid into surrounding cabinetry with clearance
dimensions slightly different than the standard built-in
model ICB424.
Make sure that the finished rough opening where the wine
storage unit is to be installed is properly prepared. Refer
to the installation specifications illustration for rough
opening dimensions, door swing clearance and electrical
placement for models ICB424 and ICB424FS.
IMPORTANT NOTE: To operate properly, the door must
open a minimum of 90°. Use a minimum 76 mm filler in
corner installations to assure a 90° door opening. Allow
enough clearance in front of the unit for full door swing.
IMPORTANT NOTE: Make sure the floor under the unit is
level with the surrounding finished floor.
Do not load wine into the wine storage unit until the
installation is complete.
TOP VIEW
610 mm
ROUGH
OPENING
DEPTH
ROUGH OPENING
WIDTH
610 mm
MODEL ICB424
619 mm
MODEL ICB424FS
MODEL ICB424
ANTI-TIP BRACKET
LOCATE ELECTRICAL
WITHIN SHADED AREA
114
mm
394 mm
E
64 mm
MODEL ICB424FS
FRONT VIEW
ANTI-TIP BRACKET
145˚
90˚
MAXIMUM
DOOR SWING
644
mm
660 mm
1118 mm
DOOR CLEARANCE
DOOR CLEARANCE
Door swing clearances are based on stainless steel door and
handle dimensions.
Electrical Requirements
A 220-240 V AC, 50/60 Hz, 10 amp circuit breaker and
electrical supply are required. A separate circuit, servicing
only this appliance, is required.
The power supply cord has a grounding plug, which must
be plugged into a mating ground ing-type wall recep tacle.
Follow local codes and ordinances when installing the
receptacle. For location of the electrical supply, refer to
the installation specifications illustration to the left.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
876 mm
ROUGH
OPENING
HEIGHT
HOME ALARM SYSTEM
870 mm
MINIMUM
If a home alarm system is to be used, refer to home alarm
HEIGHT
REQUIRED
connections on page 8. In addition to operating power, the
installer may also be required to supply a home automa-
tion system lead to the unit. This is for a low-voltage, low-
current signal similar to door and window sensor signals.
Common, normally open and normally closed contact
configurations are provided.
Three 6 mm female spade connectors are located in the
compressor compartment and are accessible behind the
kickplate on models ICB424 and ICB424FS. A minimum of
606 mm
914 mm of lead wire should be provided for each contact,
exiting the back wall near the electrical outlet.
Do not use an extension cord or two-prong adapter.
645 mm
Electrical ground is required on this appliance.
subzero.com
Unpacking and Moving
Uncrate the unit, remove its wood base and discard the
shipping bolts that hold the wood base to the bottom of
the unit. Remove all packing materials and tape.
IMPORTANT NOTE: Do not discard the kickplate, anti-tip
bracket and hardware. These items will be needed for the
installation.
All roller-assembly wine shelves should be removed to
reduce weight and prevent them from rolling. To remove,
pull the shelf out to its full extension, gently and evenly lift
up on both sides of the front of the shelf and remove.
Reverse the procedure to reinstall the shelf.
Use an appliance dolly to move the wine storage unit.
Position the dolly at the back of the unit to prevent
damage to finished surfaces.
Before moving the wine storage unit in to position,
protect any finished flooring with appropriate mate-
rials and secure the door closed.
5