Sub-Zero ICB424 Instrucciones De Instalación página 22

Ocultar thumbs Ver también para ICB424:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Model ICBWS-30 Installation
Anchoring
After door and side panels have been installed, the unit
has been leveled and door adjustment completed, anchor
the wine storage unit to the opening. This will assure a
proper fit and a secure installation.
IMPORTANT NOTE: Be sure to level and square the unit
before anchoring it.
To anchor the unit to cabinetry, open the grille, and install
the screws provided through the grille frame into the cabi-
netry. There are several hole locations provided. Check for
proper door clearance by fully opening the door. Refer to
the illustration below.
Next, drill a screw through the side hole inside the roller
base assembly. There is one on each side. The screw will
need to go in at an angle in order to attach properly.
In a flush inset application, additional material may be
needed behind the cleat to ensure sufficient anchoring.
If the screws provided are not suitable for your
application, you must provide adequate screws.
ANCHORING
SCREWS
ANCHORING
Top anchoring.
Bottom anchoring.
Home Alarm Connections
If a home alarm system is to be installed on the wine
storage unit, the connections should be made using the
logic supplied with the alarm specifications. Refer to the
illustration for the appliance lead locations, and refer to
the following for color codes:
Normally open contacts – white with red stripe wire
Normally closed contacts – white with blue stripe wire
Common – gray with white stripe wire
Use the 6 mm spade terminals or wire nuts provided to
make the proper wiring connections.
IMPORTANT NOTE: If you are not responsible for alarm
system connection, this information should be supplied to
the home security system contractor.
The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be
used to switch line power.
Any unused terminals should be completely insu-
lated and all wires should be secured away from
conductive or moving components.
HOME ALARM
CONNECTIONS
SCREW
Home alarm connections.
Complete the Installation – Model ICBWS-30/S
For overlay and flush inset applications, refer to the fol-
lowing pages for front and side panel information.
Before installing the kickplate, be sure to reinstall the drain
pan. Once the drain pan is in place, screw the kickplate
the to brackets attached to the inside surface of each
roller base. Reinstall the grille following the instructions on
page 13. Turn power back on to the electrical outlet.
90° Door Stop
The door of the model ICBWS-30 opens to 110°. A 90°
door stop ships with the unit and is located behind the
flip-up grille. Additional 90° door stop kits (7005865) are
available through your Sub-Zero dealer.
The 90° door stop will be installed in the top hinge of the
door. To install, open the door to approximately 90°. At the
top of the door, insert the door stop down between the
door hinge and the door closer arm. Insert the screw
through the door stop and into the door as shown in the
illustration below.
90° door stop.
Panel Installation
Before you install the front panel, refer to panel specifica-
tions for overlay or flush inset applications and be sure
you are working with the panel design called for in your
installation. If your customer has chosen the stainless
steel design, the unit has been shipped complete with a
finished stainless steel look. It will not be necessary to
install a front panel or handle hardware. In your final
preparation for stainless steel units, use a stainless steel
cleaner to remove any marks. Abra sive cleaners should
not be used, as they may scratch the surface.
If your customer has ordered an overlay model, you will
be installing a front panel to give the unit the custom
Sub-Zero look.
IMPORTANT NOTE: For overlay models, there are two
design applications—overlay and flush inset. Be sure to
use the correct panel size for your application.
22
Tabla de contenido
loading

Este manual también es adecuado para:

Icb424fsIcb427Icb427r

Tabla de contenido