Ribind SUPER 2200 FAST Manual De Instrucciones página 32

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
ACCESSORIES -
E
XTRA FUNCTIONS WITH
Code ACG5470
!! FEED THE EXP CARD IN WHEN POWER IS NOT SUPPLIED !!
LÉGENDE
ATTENTION: Before connecting the connector 11, intended for safety
edge during opening, make sure that the version of the software of
the command card is:
- v. 02 or later versions => for
BC07052);
software version
In case the version of the software is earlier than the one indicated do
not use the connector 11, LEAVE IT FREE.
CAPTION
TR => Adjustment trimmer for the courtesy light time
1-2 => 24Vac power supply for photocells, FOTOOSTA units etc....
3-4 => Traffic light 1 contact
5-6 => Traffic light 2 contact
7-8 => Courtesy light contact
9
=> Photocell 2 contact (NC)
10
=> Pedestrian opening command (NO)
11
=> Contact for safety edge (NC) (ATTENTION - see previous
note)
12
=> Common unit
E
XPANDER
CARD LED SIGNALS
D2 photocell 2 contact signal
D3 Signal for pedestrian opening contact
D4 Signal for safety edge
D5 voltage available
N.B.: LED D2, LED D4 and LED D5 must always be turned on for a
correct functioning .
PEDESTRIAN OPENING BUTTON (10-12)
This command operates the partial opening of the gate and Its closing.
When the gate Is partly open, it is not possible to operate its total
opening using the pedestrian command.
It is first necessary to close the gate than to open it totally.
NB: From modification SW.07 on cards KS and KS Super,
operation of the gate is as follows: during the opening stroke,
the pause or the pedestrian closure, it is possible to start the
opening from any control connected to the card KS or KS Super.
Through DIP 5 it is possible to choose the mode of function of the
pedestrian command.
If DIP5 is set on OFF position => It is a cyclic command. Every
If DIP5 is set on ON position => Commands the opening when gate
For the connections and the technical data of the optional equipments follow the relevant
handbooks.
EXPANDER
command card KS (BC07050 e
D5
D4
D3
D2
command operates a change; e.g.
open-stop-close-stop-open etc.
is closed. If another command is
sent during the opening of the gate
LEARNING PROCEDURE FOR THE PEDESTRIAN OPENING
When the gate is closet and the closing limit switch is engaged
1 - First position the DIP2 on mode ON (the LED DL5 blinks quickly)
and then DIP1 on mode ON (The LED DL5 blinks slowly).
2 - Press the pedestrian button (10-12) => The sliding gate opens.
3 - Press the pedestrian button to stop the travel (thereby determining
the gate opening).
4 - Wait the time you want the gate to remain open (excluded by DIP3
on OFF), then press the pedestrian button to start the closing.
5 - Position DIP1 and 2 on mode OFF after the closing limit switch
has been reached.
Safety devices are active during the programming and their intervention
stops it (the LED blinks no more but remains constantly turned on).
To repeat the programming, position DIP1 and 2 on mode OFF, close
the gate and repeat the procedure described above.
AUTOMATIC PEDESTRIAN CLOSING
Pause times before the automatic pedestrian closing of the gate are set
during the programming procedure.
The max. pause time is 5 minutes.
You can start or stop the pause time using DIP3 (ON starts).
SAFETY EDGE (11-12)
If the safety edge intervenes during the opening of the gate, it
commands the reversal of the movement. This reversal will continue
even if the safety edge remains pressed. During closing the safety edge
is not active.
NB: from modification SW.07 on cards KS and KS Super,operation
of fence is as follows:
- during opening stroke, if resistance is encountered, motion is
reversed to close;
- during closure stroke, if resistance is encountered; motion is
reversed to opening
- in case resistance load persists, a further inversion is initiated
after 2 seconds, followed by a third short inversion and thus
signalling an alarm for fence failure or jamming (contact NO).
- in case the fence remains blocked (contact NO), no further
motion is allowed.
PHOTOCELL 2 (9-12)
If it detects an object during the opening cycle, it then operates the
closing of the gate at the end of the interposition. If it detects one during
the closing cycle, it then operates the opening at the end of the
interposition.
This function is particularly helpful when you want the gate to close
immediately after you passed it. If it is not used, jumper the terminals
9-12.
COURTESY LIGHT (7-8)
It is possible to supply 24Vdc power to the coil of a relay, so as to feed
one lamp or more for a minimum period of 1 second and for a maximum
period of 4 minutes (controlled by the TR trimmer fitted on the
EXPANDER card). The relay is activated at every opening or closing.
TRAFFIC LIGHT CONTROL
When the gate is closed, the traffic light is turned off.
The red light (3-4) turns on when the gate opens.
The green light (5-6) turns on when the gate is open and the red light
turns off.
The green light remains turned on until the automatic closing starts.
When the gate closes, the green light turns off and the red light turns
on.
When the closing Is finished, the traffic light turned off.
it will have no effects. Commands
the closing when the gate id
opened.
If another command is
sent during the closing of the gate
it will re-open the gate.
Tabla de contenido
loading

Este manual también es adecuado para:

Super 2200