Electric Connections - Ribind SUPER 2200 FAST Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B

ELECTRIC CONNECTIONS

- A -
CONNEXIONS
Obligatory software version 07 FAST or following
versions FAST.
ELECTRONIC BOARD KS V.07 FAST
J1
EXP.
Connector for EXPANDER card
J2
SEC.TRANSF.
Connector for secondary transformer
J3
L 1 - N
Power supply 230 Vac 50/60 Hz
PRI.TRANSF.
J4
Connector for primary transformer
J5
DO NOT TOUCH THE JUMPER !IF IT IS
REMOVED THE OPERATOR DOESN'T MOVE !
J6
SEC.LOCK
Connector to the manual release safety device
ENCODER
J7
Not available
CAPACITOR
J8
Connector to the capacitor
J9
Connector for limit switch connection
LSO
Limit switch contact stopping the motor opening
COM.
Contacts common unit
LSC
Limit switch contact stopping the motor closing
MOTOR
J10
Connector for Motor
J11
Blinker (max. 40W )
J12
AERIAL
Radio Antenna
COM
Contacts common unit
PHOT.1 NC
Photocells contact (NC)
J13
INVERTER
NOT APPLICABLE
STOP
J14
Contact of the stop button (NC)
OPEN
Contact of the opening button (NO)
CLOSE
Contact of the closing button (NO)
K BUTT.
Contact of a single impulse (NO)
A*A
24 Vac accessories power supply
SIGNAL
Warning light - gate open 12Vdc
BUZZER
Buzzer - Wiring acoustic warning (12Vdc max
200 mA) - PAY ATTENTION TO THE POLARITY -
RADIO
J15
Connector for radio receiver 24Vac
HEATER
J16
Heater Card Connector
J17
INVERTER
NOT APPLICABLE
TRIMMER
R2
To adjust the speed of the deceleration, both in
LOW SPEED
opening and closing
TRIMMER
R9
To adjust the force of the operator through
TORQUE
the electronic clutch
code BC07050
Tabla de contenido
loading

Este manual también es adecuado para:

Super 2200

Tabla de contenido