Installation; Hydraulic Installation - Ecolab EcoPro Serie Instrucciones De Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 368
Assembly, installation, modification and upgrades
6.3

Installation

Some of the graphics shown in this chapter are schematic diagrams which are
intended to represent the general installation. The installation examples and
applications shown here are of a functional nature. They provide an overview
of correct forms of installation, or approaches to be avoided, in order to ensure
that it works properly.
6.3.1

Hydraulic installation

Personnel:
Installation diagram:
Using a multi-function valve (MFV):
Dosing, pressure retention and overpressure valves (pos. 1 and pos. 2) can be
replaced by a multifunction valve (MFV) (pos. 3) from our product range, which
combines all these functions. When using a multifunction valve, it is essential
to observe the corresponding instructions
When using a metering valve, metering spikes < 1.2 mPa (12 bar) may occur.
This means that the pump displays an error and stops.
Troubleshooting:
1.
Check back-pressure!
2.
Check all valves on the metering lines; it may be that a valve fitted in the metering
line is not opening correctly or may even be closed.
3.
Check the system pressure, and reduce if necessary.
417102264 Rev. 5-01.2019
Mechanic
n
n
Service personnel
n
Specialist
1 Overflow valve
2 Pressure control valve
3 Option: Multi-function valve (MFV)
4 Suction lance or floor suction valve
D Pressure valve
P Pump head
S Suction valve
34
.
Tabla de contenido
loading

Tabla de contenido