C. Installation instruction
8. When unit operation, put the unit in a well-ventilated place and non-blocking the air vent, so that the
machine can be able to inhale and exhaust enough air, to achieve hot water supply function. \
9. The appliance can work without air duct.
10. There should be with drain around the system unit for drainage. And the surrounding should have
enough space for maintenance. Because the top cover can be opened, at the top side of the unit
should have ≥800mm space for maintain.
12. The water temperature sensor is fixed in the temperature tube in the tank and adhesive sealed well
by the factory. When installing, there is no need to fix another one.
13. This water heater unit is filled with refrigerant by the factory, and no need to vacuumize or refill
refrigerant.
Installation of the solar collectors (solar connection only available in the E301WHF
model)
1. When installing the solar collectors, the optimized solution is toward due south (note: due north for
south hemisphere). Its obliquity α should be equal to the local latitude. If the major working time for
the product are summer days, the obliquity α should be the figure that local latitude minus 10
major working time for the product are winter days, the obliquity α should be the figure that local
°.
latitude plus 10
2. Considering the product is mostly working in the winter, it is suggested that the obliquity α should be
the figure that local latitude plus 10
3. The solar collectors should be installed in a place where has reliable load bearings and enough
sunshine, such as flat land, roof, shed roof etc.
4. If the product needs the supporting frame for installation, the height between the ground and lower
end of the solar collectors ranges between 100 and
300mm.
5. Generally, the dimension of the solar collectors is
2m× 1m, the net weight is about 34Kg.
6. The solar collectors is usually installed in a place
where is a little high and open. Hence the installation
should be steady enough to resist the wind.
7. When using in a freezing area, please adopt the
second circulation system (solar coil in the water
tank) without fail. The heat-conducting medium
should
be
anti-freezing
suggested). (Note: in such area, the once circulation
"tank water to solar water" is forbidden to use).
8. If there is no demand for hot water for a long time,
the surface which towards sunshine should be
covered
by
opaque
overheating.
(Fig.4)
°.
(e.g. the local latitude is 28
liquid
substances
(propanediol
to
avoid
4
°
, the obliquity α should be 38°)
(Fig.4 )
°.