Commissioning - Honeywell HCW 82 Montaje Y Funcionamiento

Sensor a distancia/sensor de temperatura ambiente
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
Contents
1.
Overview ............................................................... 7
1.1.
Application............................................................. 7
1.2.
Differences HCW 82/HCF 82 ................................ 7
1.3.
Scope of delivery................................................... 7
2.
Commissioning...................................................... 7
2.1.
Teach-in ................................................................ 8
2.1.1.
2.1.2.
2.1.3.
function.................................................................. 8
2.1.4.
Failed teach-in....................................................... 8
2.2.
Installation ............................................................. 8
3.
Particular features of HCW 82............................... 9
3.1.
Operation .............................................................. 9
3.2.
Limiting the adjustment range ............................... 9
3.3.
3.4.
Installing the window contact............................... 10
4.
Changing batteries .............................................. 10
5.
Checking radio transmission ............................... 10
6.
Help with problems.............................................. 10
7.
Technical data ..................................................... 10
8.
and Electronic Equipment directive ..................... 10
1.
Overview
The HCW 82/HCF 82 room devices are used for intelligent
room temperature control. The room temperature sensor
HCF 82 measures the room temperature and sends the
measured values to other devices.
The HCW 82 measures the room temperature and
additionally allows the room setpoint temperature to be
adjusted.
1.1.
Application
The room devices transfer the data with 868.3 MHz. The
data can be received by other devices such as the
underfloor heating controller HCE 80/HCC 80/HCE 80R/
HCC 80R or the Hometronic Manager HCM 200D.
Thus a large spectrum of applications can be covered -
from individual room control to frost protection control.
1.2.
Differences HCW 82/HCF 82
The HCW 82 has the following functions in addition to those
of the HCF 82:
• Connection possibility for an external power supply unit
(see "Operation with an external power source", Page 9).
• Connection possibility for a window contact
(see "Installing the window contact", Page 10).
• Adjustment dial at which you can change the room
temperature setpoint directly.
The adjustment range amounts to ± 12 °C, starting from
the basic value of 20 °C (in position 0).
1.3.
Scope of delivery
• 1 HCW 82/HCF 82
• 2 AA batteries
2.

Commissioning

WARNING
Insufficient data transfer!
Interference of the radio receiver in the
device through metallic objects or
further radio devices.
Ensure there is sufficient distance to
metallic objects.
Mount the device with a distance of at
least 1 m to radio devices such as
radio headphones, cordless phones
according to the DECT standard, etc.
Select another installation site if the
radio interference cannot be rectified.
2
1
Fig. 1: Removing the housing cover
Remove the housing cover of the room temperature
sensor (see Fig. 1
).
Fig. 2: Battery polarity and Send button
Insert the supplied AA batteries with the correct battery
polarity (see Fig. 2).
The batteries have to be replaced when the red LED at the
HCW 82/HCF 82 flashes (see "Changing batteries",
Page 10).
The setpoint adjuster HCW 82 can also be
operated with an external power source instead
of with batteries. Further information can be
found in section "Operation with an external
power source", Page 9.
Place the room temperature sensor at the installation site,
but do not install it yet.
Allocate the corresponding temperature zone to the
HCW 82/HCF 82 (see "Teach-in").
Overview
Red LED
Send button
7
Tabla de contenido
loading

Este manual también es adecuado para:

Hcf 82

Tabla de contenido