1. GENERAL WARNINGS

Carefully read and follow the instructions contained in this instruction booklet.
After boiler installation, inform the user regarding its operation and give him this
manual, which is an integral and essential part of the product and must be kept with
care for future reference.
Installation and maintenance must be carried out by professionally qualified person-
nel, in compliance with the current regulations and according to the manufacturer's
instructions. Do not carry out any operation on the sealed control parts.
Incorrect installation or inadequate maintenance can result in damage or injury. The
Manufacturer declines any liability for damage due to errors in installation and use,
or failure to follow the instructions.
Before carrying out any cleaning or maintenance operation, disconnect the unit from
the electrical power supply using the switch and/or the special cut-off devices.
In case of a fault and/or poor operation, deactivate the unit and do not try to repair
it or directly intervene. Contact professionally qualified personnel. Any repair/re-
placement of the products must only be carried out by qualified personnel using orig-
inal replacement parts. Failure to comply with the above could affect the safety of
the unit.
This unit must only be used for its intended purpose. Any other use is deemed im-
proper and therefore hazardous.
The packing materials are potentially hazardous and must not be left within the
reach of children.
The unit must not be used by people (including children) with limited physical, sen-
sory or mental abilities or without experience and knowledge of it, unless instructed
or supervised in its use by someone responsible for their safety.
The unit and its accessories must be appropriately disposed of, in compliance with
the current regulations.
The images given in this manual are a simplified representation of the product. In
this representation there may be slight and insignificant differences with respect to
the product supplied.
2. OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
Thank you for choosing GASTER 56 N AW, a floor-standing boiler LAMBORGHINI fea-
turing advanced design, cutting-edge technology, high reliability and quality construc-
tion. Please read this manual carefully and keep it for future reference.
GASTER 56 N AW is a high-efficiency heat generator for central heating using natural
gas or liquefied gas (configurable at the time of installation) and regulated by an ad-
vanced electronic control system.
The boiler shell consists of cast-iron elements whose particular shape guarantees high
exchange efficiency under all operating conditions and an open-flue burner equipped
with electronic ignition and ionization flame control.
The boiler is also equipped with a temperature limiter (safety thermostat) and a fume
evacuation control device (fume thermostat).
Thanks to the electronic flame control and ignition system, boiler operation is mostly au-
tomatic.
The user only has to set the temperature required inside the home (by means of the op-
tional room thermostat, whose installation is recommended) or adjust the temperature of
the system.

2.2 Control panel

1
fig. 1 - Control panel
Key
1
Thermostatic Controller arrangement
2
Boiler pressure/temperature gauge
3
Fume thermostat cover
4
Flame controller reset button with shutdown indicator
5
Boiler control thermostat
6
0-1-Test switch
7
Automatic reset safety thermostat (inside the panel)
2
3
4
5
cod. 3541A171 - Rev. 01 - 03/2018

2.3 Turning on and off

Lighting
Open the gas cock ahead of the boiler
Turn on the switch or insert the plug (if present) ahead of the boiler
Turn the main switch "6" to position 1 (fig. 1).
Turn the knob "5" to the selected temperature and that of the room thermostat (if
present) to the required temperature value. The burner will light and the boiler be-
gins to function automatically, controlled by its adjustment and safety devices.
If the boiler is equipped with an electronic thermostatic controller fitted in position 1
of fig. 1, the user must also take into account the manufacturer's instructions.
If the burners do not light and the pushbutton-shutdown indicator 4 comes on
A
after correctly carrying out the lighting procedures, wait about 15 seconds and
then press the above pushbutton. The reset controller will repeat the lighting cy-
cle. If the burners do not light even after several attempts, contact an authorised
service centre or qualified personnel.
Turning off
Close the gas cock ahead of the boiler, turn knob "6" to 0 and disconnect the power to
the unit.
B
To avoid damage caused by freezing during long idle periods in winter, it is ad-
visable to drain all water from the boiler and system; or add a suitable antifreeze
to the heating system.
The boiler switch 6 has 3 positions "0-1-TEST"; the first two have the on-off
function, the third (unstable) must only be used for service and maintenance
purposes.
2.4 Adjustments
System temperature adjustment
Turn the knob 5 of fig. 1 clockwise to increase the heating water temperature, or anti-
clockwise to decrease the temperature. The temperature can be varied from a minimum
of 30°C to a maximum of 90°C. However, it is advisable not to operate the boiler below
45°C.
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the required room temperature. Controlled by the room
thermostat, the boiler lights and brings the system water to the temperature set by boiler
control thermostat 5 of fig. 1. The generator turns off when the required temperature in
the rooms is reached.
If the room thermostat is not present, the boiler will keep the system at the temperature
set by the boiler control thermostat.
Water system pressure adjustment
The filling pressure with system cold, read on the boiler water gauge detail 2 of fig. 1,
must be approx. 1.0 bar. If, during operation, the system pressure falls (due to the evap-
oration of gases dissolved in the water) to values below the minimum described above,
the User must bring it to the initial value by operating the filling cock. At the end of the
operation always close the filling cock.
2.5 Maintenance
The user must have the heating system serviced by qualified personnel at least once a
year and combustion checked at least every two years. Consult sec. 4.3 of this manual
for more information.
The boiler casing, panel and aesthetic parts can be cleaned with a damp soft cloth, if nec-
essary soaked in soapy water. Do not use abrasive detergents and solvents.
2.6 Faults
Given below are the faults that can be caused by simple user-solvable problems.
Before calling the After-Sales Service check if the problem is due to no gas or
A
electricity.
Symbol Faults
Boiler shutdown by the flame controller
Boiler shutdown due to insufficient system pressure (only
if a water pressure switch is installed)
6
7
Boiler shutdown due to insufficient evacuation of fumes
Cure
Make sure that the gas cocks ahead of the
boiler and on the meter are open.
Press the lit pushbutton-indicator.
In case of repeated boiler shutdowns, contact
the nearest service centre.
Fill the system to 1-1.5 bar cold by means of
the system filling cock.
Close the cock after use.
Unscrew the fume thermostat cover and press
the button below.
In case of repeated boiler shutdowns contact
the nearest service centre.
11
EN