Drawing water
Insert a coin in the coin slot.
Press the water dispenser button.
Hold the fuel pump nozzle in
the container opening.
Pull the fuel pump nozzle lever
until the desired filling level has
been reached.
Checking tyre pressure
Insert a coin in the coin slot.
Press the tyre pressure button.
Secure the valve connector on
the tyre valve.
Read the tyre pressure at the
pressure gauge.
Increase the tyre pressure by
pressing the "+" button.
or
Decrease the tyre pressure by
pressing the "–" button.
Remove the valve connector.
Pull on the hose briefly and
feed the hose via the automatic
hose reel.
Settings
Setting the run time
Note:
The adjustable run time applies to the in-
sertion of one of the following coins:
– 50 Eurocents
– 50 British pence
– 1 Swiss franc
– 1 Polish złoty
– 5 Norwegian Kroner
Customer Service can set up different
types of coins.
1 Rotary knob
Adjust the run time per unit at the P I ro-
tary knob.
Possible setting range: 30 seconds to
7 minutes.
Note:
Rotary knobs P II, P III and P IV have no
function.
Frost protection
Device with frost protection
1 Frost protection switch
2 Frost protection heater
Turn the frost protection switch "ON" at
temperatures below +5 °C.
ATTENTION
Risk of damage due to frost. The frost pro-
tection heater is active only when the main
switch is also "ON".
Note:
The frost protection heater is not thermo-
stat-controlled. When switched on, the
heater is continuously in use.
Device without frost protection
In a device without frost protection, a shut-
down must be carried out if there is risk of
frost
Shutting down
Shut off water supply.
Drain the condensate in the com-
pressed air reservoir (see "Mainte-
nance tasks").
Set the main switch to the "OFF" posi-
tion.
Shutdown during Frost Conditions
Shut off water supply.
Remove water from the device and sup-
ply line.
Drain the condensate in the com-
pressed air reservoir (see "Mainte-
nance tasks").
Set the main switch to the "OFF" posi-
tion.
Maintenance and care
Daily
Empty the coin cassette (see "Mainte-
nance tasks").
Check the general condition of the de-
vice.
Check the condition of the valve con-
nector.
Check status of hose pipes.
Open the lower cover and check the
condition of the compressor.
Have damaged parts replaced.
Weekly
Clean the external surfaces of the appli-
ance.
Drain the condensate in the com-
pressed air reservoir (see "Mainte-
nance tasks").
2
-
EN
Maintenance Works
Emptying the coin cassette
1 Door
2 Coin cassette
Open door.
Remove and empty the coin cassette.
Drain off the condensate.
1 Cover
2 Condensate drain valve
Remove cover.
Hold the condensate drain valve over a
duct or a collection container.
WARNING
Risk of injury from the water stream.
Never direct the water jet on human beings,
animals, the appliance or electrical parts.
Open the condensate drain valve slow-
ly and drain the condensate.
Close the condensate drain valve.
Replace cover.
7