Modes of operation
"Central" (Z)
Application example: A shutter control flush-mounted
insert is used as a central control unit for other
shutters.
Any actuation (short or long) of this central control unit
is interpreted as a motion command (3 minutes) and
put into effect. In this way,r it is ensured that all
subordinate shutters move to the end position.
Programmed down motion times are carried out for the
extension units.
Programming (P)
Application example: A move down command
automatically moves the shutter downwards to a
specified position and adjusts the louvres.
After change-over to another mode of operation, the
programmed motion time is only active if the shutter
was moved upwards beforehand by a motion
command (3 minutes) - only in this manner is it
ensured that the desired position is approached.